Perivascular CSF T2 Values compared to Sulcal and Lateral Ventricular CSF: a window into brain clearance pathways

Motivation: Earlier studies have measured CSF-T2 values in the sulci and ventricles of healthy subjects; however, these studies lacked sufficient resolution to assess the perivascular spaces (PVS). Goal(s): We obtained high-resolution multi-echo scans at 7T and compared PVS T2 values with those in the sulci and lateral ventricles. Approach: We hypothesized that T2 values in the PVS would be lower due to the presence of 'dirty' CSF closer to waste production sites. Six subjects were acquired with multi-echo 7T scans with long echo times, and T2 maps were created. Results: PVS had shorter T2 values than the sulci and lateral ventricles. Impact: The reduced T2 values observed in the PVS suggest the presence of 'dirty' CSF, supporting the idea that MR-visible PVS, primarily associated with arteries, may serve not only as channels for fresh CSF inflow but as mixing-sites of waste products.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0021
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perivascular CSF T2 Values compared to Sulcal and Lateral Ventricular CSF: a window into brain clearance pathways

Emiel Roefs, Martijn Nagtegaal, Matthias J.P. van Osch, Nina E. Fultz et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Cerebrospinal fluid and hydrocephalus
article

Perivascular CSF T2 Values compared to Sulcal and Lateral Ventricular CSF: a window into brain clearance pathways

Emiel Roefs, Martijn Nagtegaal, Matthias J.P. van Osch, Nina E. Fultz, Lydiane Hirschler
article en

Abstract

Motivation: Earlier studies have measured CSF-T2 values in the sulci and ventricles of healthy subjects; however, these studies lacked sufficient resolution to assess the perivascular spaces (PVS). Goal(s): We obtained high-resolution multi-echo scans at 7T and compared PVS T2 values with those in the sulci and lateral ventricles. Approach: We hypothesized that T2 values in the PVS would be lower due to the presence of 'dirty' CSF closer to waste production sites. Six subjects were acquired with multi-echo 7T scans with long echo times, and T2 maps were created. Results: PVS had shorter T2 values than the sulci and lateral ventricles. Impact: The reduced T2 values observed in the PVS suggest the presence of 'dirty' CSF, supporting the idea that MR-visible PVS, primarily associated with arteries, may serve not only as channels for fresh CSF inflow but as mixing-sites of waste products.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 73%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.