Innovation of a bio-approximate magnetic resonance imaging phantom: Approach to optimize relaxation time and proton density

Motivation: The relaxation time of most magnetic resonance phantoms is equivalent to that of the target organ. If the proton density, the differences in which are not discussed, is adjusted, studies can be performed using only phantoms. Goal(s): To develop a phantom with an adjustable proton density and relaxation time equivalent to a living body. Approach: The solvent was a solution of hydrogen peroxide, water, and a carboxy-vinyl polymer. Nickel chloride, trisodium phosphate, and powdered acrylic were used for T1, T2, and proton adjustments, respectively. Results: A phantom was developed with bio-approximate relaxation times and an adjustable proton density. Impact: Phantoms with adjustable relaxation times and proton densities can be studied similarly to imaging a living body. This development is a powerful tool for analyzing performance and image characteristics and can be applied to quantitative MRI evaluation.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/5377
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovation of a bio-approximate magnetic resonance imaging phantom: Approach to optimize relaxation time and proton density

Akihiro Yamashiro, Tomoki Kaneko, Kazuki Sato, Kaoru Ootuka
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Innovation of a bio-approximate magnetic resonance imaging phantom: Approach to optimize relaxation time and proton density

Akihiro Yamashiro, Tomoki Kaneko, Kazuki Sato, Kaoru Ootuka
article en

Abstract

Motivation: The relaxation time of most magnetic resonance phantoms is equivalent to that of the target organ. If the proton density, the differences in which are not discussed, is adjusted, studies can be performed using only phantoms. Goal(s): To develop a phantom with an adjustable proton density and relaxation time equivalent to a living body. Approach: The solvent was a solution of hydrogen peroxide, water, and a carboxy-vinyl polymer. Nickel chloride, trisodium phosphate, and powdered acrylic were used for T1, T2, and proton adjustments, respectively. Results: A phantom was developed with bio-approximate relaxation times and an adjustable proton density. Impact: Phantoms with adjustable relaxation times and proton densities can be studied similarly to imaging a living body. This development is a powerful tool for analyzing performance and image characteristics and can be applied to quantitative MRI evaluation.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.