On the feasibility of myelin water imaging at low-field MRI using multi-echo GRASE

Motivation: Low-field MRI may offer benefits for myelin water fraction (MWF) mapping due to the longer T2 of water and more homogeneous B0 and B1+ fields compared to higher field strengths. Goal(s): To investigate a multi-echo GRASE sequence for MWF mapping at 0.55T. Approach: Four healthy volunteers were scanned using a multi-echo GRASE sequence with GRAPPA x2 and 2x2 acceleration. Images were reconstructed using both conventional GRAPPA and a deep learning-based method. Resulting MWF maps were compared visually and using a Bland-Altman analysis. Results: Using GRAPPA 2x2 and deep-learning reconstruction, good quality MWF maps in agreement with GRAPPA x2 could be obtained in 6:41$$$\,$$$minutes. Impact: By leveraging deep learning-based reconstructions, myelin water imaging is feasible at 0.55T with a multi-component decomposition of multi-echo T2 data acquired in approximately 6 minutes at 2.5 mm isotropic resolution, encouraging further neuroimaging research at low field strengths.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/5200
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the feasibility of myelin water imaging at low-field MRI using multi-echo GRASE

Tom Hilbert, Dominik M. Nickel, Erick Jorge Canales-Rodríguez, Bénédicte Maréchal et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

On the feasibility of myelin water imaging at low-field MRI using multi-echo GRASE

Tom Hilbert, Dominik M. Nickel, Erick Jorge Canales-Rodríguez, Bénédicte Maréchal, Gian Franco Piredda, Tommaso Di Noto, Thomas Yu, Tobias Kober, Lina Bacha
article en

Abstract

Motivation: Low-field MRI may offer benefits for myelin water fraction (MWF) mapping due to the longer T2 of water and more homogeneous B0 and B1+ fields compared to higher field strengths. Goal(s): To investigate a multi-echo GRASE sequence for MWF mapping at 0.55T. Approach: Four healthy volunteers were scanned using a multi-echo GRASE sequence with GRAPPA x2 and 2x2 acceleration. Images were reconstructed using both conventional GRAPPA and a deep learning-based method. Resulting MWF maps were compared visually and using a Bland-Altman analysis. Results: Using GRAPPA 2x2 and deep-learning reconstruction, good quality MWF maps in agreement with GRAPPA x2 could be obtained in 6:41$$$\,$$$minutes. Impact: By leveraging deep learning-based reconstructions, myelin water imaging is feasible at 0.55T with a multi-component decomposition of multi-echo T2 data acquired in approximately 6 minutes at 2.5 mm isotropic resolution, encouraging further neuroimaging research at low field strengths.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.