Automated Estimation of White Matter Hyperintensity Burden from 2D T2w TSE as an Alternative to 3D FLAIR

Motivation: FLAIR imaging is sensitive for detecting white matter hyperintensities (WMHs) but sometimes unavailable due to lengthy acquisition times. Goal(s): To assess 2D T2w TSE sequences as an alternative to 3D FLAIR for the automated estimation of WMH volumes. Approach: WMHs were segmented from FLAIR images, and the images were registered to TSE images. Two neural networks were trained for skull stripping and WMH segmentation on TSE images. Separate test sets with paired FLAIR/TSE were used to evaluate the method. Results: TSE-based segmentation correlated strongly with FLAIR (TIV: 0.98, WMH: 0.95), demonstrating suitability of TSE for estimating total WMH volume. Impact: Using 2D T2w Turbo Spin Echo (TSE) sequences for white matter hyperintensity (WMH) volume estimation provides a dependable alternative to 3D FLAIR, particularly when quick scan protocols are necessary, but WMH estimation is still needed.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1511
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Estimation of White Matter Hyperintensity Burden from 2D T2w TSE as an Alternative to 3D FLAIR

Veronica Ravano, Tom Hilbert, Emmanuelle Le Bars, Jonathan A. Disselhorst et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Neuroimaging Techniques and Applications
article

Automated Estimation of White Matter Hyperintensity Burden from 2D T2w TSE as an Alternative to 3D FLAIR

Veronica Ravano, Tom Hilbert, Emmanuelle Le Bars, Jonathan A. Disselhorst, Vincent Dunet, Bénédicte Maréchal, Hagen H. Kitzler, Tommaso Di Noto, Gilles Allali, Nicolas Menjot de Champfleur
article en

Abstract

Motivation: FLAIR imaging is sensitive for detecting white matter hyperintensities (WMHs) but sometimes unavailable due to lengthy acquisition times. Goal(s): To assess 2D T2w TSE sequences as an alternative to 3D FLAIR for the automated estimation of WMH volumes. Approach: WMHs were segmented from FLAIR images, and the images were registered to TSE images. Two neural networks were trained for skull stripping and WMH segmentation on TSE images. Separate test sets with paired FLAIR/TSE were used to evaluate the method. Results: TSE-based segmentation correlated strongly with FLAIR (TIV: 0.98, WMH: 0.95), demonstrating suitability of TSE for estimating total WMH volume. Impact: Using 2D T2w Turbo Spin Echo (TSE) sequences for white matter hyperintensity (WMH) volume estimation provides a dependable alternative to 3D FLAIR, particularly when quick scan protocols are necessary, but WMH estimation is still needed.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies