Calibration-free DCE-MRI with Sub-second Temporal Resolution Using Interpretable Implicit Neural Representation
Motivation: Dynamic Contrast-Enhanced MRI (DCE-MRI) requires high temporal resolution to effectively capture motion and contrast dynamics. Current methods rely on pre-estimating temporal information from calibration data, limiting imaging performance. Goal(s): We aim to develop a novel reconstruction method for achieving sub-second temporal resolution in DCE-MRI without the need for calibration data. Approach: We introduce an unsupervised Implicit Neural Representation (INR) framework, where spatial coordinates and learnable temporal latent variables are used to model and reconstruct the DCE-MRI data directly. Results: Our method reconstructs artifact-free images, with even one spoke per frame, and the learned latent variables accurately capture both contrast changes and respiratory motion. Impact: The proposed method paves the way for artifact-free, high-temporal-resolution DCE-MRI for clinical applications. Moreover, the proposed INR framework makes calibrationless MRI reconstruction feasible and interpretable, offering a powerful tool for a wide range of imaging challenges.
Authors
- Jie Feng (ORCID: https://orcid.org/0000-0002-8032-7542)
- Hongjiang Wei (ORCID: https://orcid.org/0000-0002-9060-4152)
- Jingjia Chen (ORCID: https://orcid.org/0000-0002-8220-6330)
- Yuyao Zhang (ORCID: https://orcid.org/0000-0001-6706-4867)
- Dong Liang (ORCID: https://orcid.org/0000-0002-3166-4235)
- Li Feng (ORCID: https://orcid.org/0000-0002-5836-2296)
Publication Details
- Journal
- Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
- Published
- 2025-09-16
- DOI
- https://doi.org/10.58530/2025/0123
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00