Evaluating the Impact of Anatomical Motion on Cardiac 31P MRSI with a Deformable Digital Phantom

Motivation: Cardiac 31P MRSI faces unique challenges, particularly due to continuous organ motion. Low spatial resolution makes efficacy of motion correction difficult to assess. Goal(s): To develop a simulation tool that visualizes the effects of cardiac and respiratory motion on spectral signal quality, enabling quantification of motion correction impacts on cardiac 31P MRSI data. Approach: A dynamic digital phantom with cardiac and respiratory motion was designed, followed by simulation of CSI acquisition and reconstruction, incorporating motion compensation. Various parameters allowed the simulation of realistic measurement scenarios. Results: Simulations confirmed the low spatial resolution as the major limiting factor for latent effect of motion correction. Impact: This simulation framework provides researchers with a tool to evaluate and optimize cardiac 31P MRSI protocols, paving the way for improved motion correction techniques that could refine in vivo measurements and metabolic assessment in clinical cardiology.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4973
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Impact of Anatomical Motion on Cardiac 31P MRSI with a Deformable Digital Phantom

A. Schmid, Stefan Wampl, Lorenz Kiss
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Evaluating the Impact of Anatomical Motion on Cardiac 31P MRSI with a Deformable Digital Phantom

A. Schmid, Stefan Wampl, Lorenz Kiss
article en

Abstract

Motivation: Cardiac 31P MRSI faces unique challenges, particularly due to continuous organ motion. Low spatial resolution makes efficacy of motion correction difficult to assess. Goal(s): To develop a simulation tool that visualizes the effects of cardiac and respiratory motion on spectral signal quality, enabling quantification of motion correction impacts on cardiac 31P MRSI data. Approach: A dynamic digital phantom with cardiac and respiratory motion was designed, followed by simulation of CSI acquisition and reconstruction, incorporating motion compensation. Various parameters allowed the simulation of realistic measurement scenarios. Results: Simulations confirmed the low spatial resolution as the major limiting factor for latent effect of motion correction. Impact: This simulation framework provides researchers with a tool to evaluate and optimize cardiac 31P MRSI protocols, paving the way for improved motion correction techniques that could refine in vivo measurements and metabolic assessment in clinical cardiology.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.