Sharing GRAPPA calibration regions to accelerate quantitative imaging with phase-cycled bSSFP

Motivation: Quantitative imaging typically relies on repeated acquisitions of data with similar contrast. When combined with GRAPPA undersampling, repeatedly acquiring calibration regions may be redundant and prolong scan time. Goal(s): To demonstrate that a single acquisition of a calibration region is sufficient for multiparametric mapping. Approach: Undersampled phase-cycled bSSFP data were acquired and reconstructed using GRAPPA, using a single calibration region which was shared across contrasts and a repeated calibration region. Results were compared with fully sampled brain data obtained in healthy volunteers. Results: The acquisition of a single calibration region reduced scan time by ~30%, while T1 and T2 quantification was not affected. Impact: Shared calibration region data across repeated acquisitions in quantitative parametric mapping sequences, significantly accelerates quantitative imaging without compromising image quality.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1690
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sharing GRAPPA calibration regions to accelerate quantitative imaging with phase-cycled bSSFP

Jessica Bastiaansen, Eva S. Peper, Piotr Radojewski, Berk Can Açikgöz et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Nuclear Physics and Applications
article

Sharing GRAPPA calibration regions to accelerate quantitative imaging with phase-cycled bSSFP

Jessica Bastiaansen, Eva S. Peper, Piotr Radojewski, Berk Can Açikgöz, Nils Plähn, Yves Moerlen
article en

Abstract

Motivation: Quantitative imaging typically relies on repeated acquisitions of data with similar contrast. When combined with GRAPPA undersampling, repeatedly acquiring calibration regions may be redundant and prolong scan time. Goal(s): To demonstrate that a single acquisition of a calibration region is sufficient for multiparametric mapping. Approach: Undersampled phase-cycled bSSFP data were acquired and reconstructed using GRAPPA, using a single calibration region which was shared across contrasts and a repeated calibration region. Results were compared with fully sampled brain data obtained in healthy volunteers. Results: The acquisition of a single calibration region reduced scan time by ~30%, while T1 and T2 quantification was not affected. Impact: Shared calibration region data across repeated acquisitions in quantitative parametric mapping sequences, significantly accelerates quantitative imaging without compromising image quality.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 68%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.