Test-Retest Precision of Brain Metabolites in Healthy Participants using 31P-MRS and 1H MEGA-PRESS at 3T Multi-nuclear MRI System

Motivation: MRS enables non-invasive quantification of brain metabolites, but its reliability is crucial for accurate interpretation. Goal(s): This study assessed the test-retest of 31P-MRS and 1H-MEGA-PRESS in measuring phosphorus-31 metabolites, GABA, GSH using a 3T system. Approach: 32 participants underwent two scanning sessions within three days. GABA+, Glx, GSH, and ten 31P metabolites were analyzed based on CV and Bland-Altman plots. Results: The CV of GPE, GPC, -ATP, -ATP, pH and Mg2+ was below 10%, PE, PC, -ATP, Pi, GPTC was over 10%. The CV of GABA+/Cr, GABA+/water, Glx/Cr, Glx/water were below 4%; GSH/Cr, GSH/water were 11.904% and 16.525%. Impact: This study reveals the range of reliability of MEGA-edited GABA+, Glx and 31P-MRS techniques in application.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3213
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test-Retest Precision of Brain Metabolites in Healthy Participants using 31P-MRS and 1H MEGA-PRESS at 3T Multi-nuclear MRI System

Wenzhen Zhu, Xiaoxiao Zhang, Shuang Hu
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Imaging Techniques and Applications
article

Test-Retest Precision of Brain Metabolites in Healthy Participants using 31P-MRS and 1H MEGA-PRESS at 3T Multi-nuclear MRI System

Wenzhen Zhu, Xiaoxiao Zhang, Shuang Hu
article en

Abstract

Motivation: MRS enables non-invasive quantification of brain metabolites, but its reliability is crucial for accurate interpretation. Goal(s): This study assessed the test-retest of 31P-MRS and 1H-MEGA-PRESS in measuring phosphorus-31 metabolites, GABA, GSH using a 3T system. Approach: 32 participants underwent two scanning sessions within three days. GABA+, Glx, GSH, and ten 31P metabolites were analyzed based on CV and Bland-Altman plots. Results: The CV of GPE, GPC, -ATP, -ATP, pH and Mg2+ was below 10%, PE, PC, -ATP, Pi, GPTC was over 10%. The CV of GABA+/Cr, GABA+/water, Glx/Cr, Glx/water were below 4%; GSH/Cr, GSH/water were 11.904% and 16.525%. Impact: This study reveals the range of reliability of MEGA-edited GABA+, Glx and 31P-MRS techniques in application.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Test-Retest Precision of Brain Metabolites in Healthy Participants using 31P-MRS and 1H MEGA-PRESS at 3T Multi-nuclear MRI System — Wenzhen Zhu, Xiaoxiao Zhang, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS