Parallel Imaging using Metasurface Resonators

Motivation: Metasurface resonators lead to a focusing of individual receive coils' sensitivity profiles, which might contradict parallel imaging methods. It has to be quantified to what degree this occurs to evaluate the feasibility of parallel imaging acceleration while using metasurfaces. Goal(s): Quantify the compatibility of wireless metasurface resonators with parallel imaging. Approach: Measurement of the inverse g-factors when using either the metasurface resonator or alternatively a conventional 4-channel coil, both combined with the table-integrated spine coil. This is done in phantom and in vivo. Results: Minor differences (Δmean ≤ 0.05) were measured particularly in anterior-posterior acceleration when compared with an alternative conventional 4-channel coil. Impact: We demonstrated and quantified the compatibility of wireless metasurface resonators with parallel imaging in phantom and in vivo. This enables future studies to expand the application area of these novel coil alternatives or develop special designs for improved parallel imaging.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3454
Primary Topic
Metamaterials and Metasurfaces Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parallel Imaging using Metasurface Resonators

Daniel Düx, Max Joris Hubmann, Robert Kowal, Holger Maune et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Metamaterials and Metasurfaces Applications
article

Parallel Imaging using Metasurface Resonators

Daniel Düx, Max Joris Hubmann, Robert Kowal, Holger Maune, Oliver Speck, Bennet Hensen, Frank K. Wacker, Ivan Vogt, Marcel Gutberlet, Lucas Knull, Niklas Paulig, Daniel Arnecke
article en

Abstract

Motivation: Metasurface resonators lead to a focusing of individual receive coils' sensitivity profiles, which might contradict parallel imaging methods. It has to be quantified to what degree this occurs to evaluate the feasibility of parallel imaging acceleration while using metasurfaces. Goal(s): Quantify the compatibility of wireless metasurface resonators with parallel imaging. Approach: Measurement of the inverse g-factors when using either the metasurface resonator or alternatively a conventional 4-channel coil, both combined with the table-integrated spine coil. This is done in phantom and in vivo. Results: Minor differences (Δmean ≤ 0.05) were measured particularly in anterior-posterior acceleration when compared with an alternative conventional 4-channel coil. Impact: We demonstrated and quantified the compatibility of wireless metasurface resonators with parallel imaging in phantom and in vivo. This enables future studies to expand the application area of these novel coil alternatives or develop special designs for improved parallel imaging.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 84%
Metamaterials and Metasurfaces Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Parallel Imaging using Metasurface Resonators — Daniel Düx, Max Joris Hubmann, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS