Improving image quality and decreasing SAR with high dielectric constant pad in 3.0T fetal MRI

Motivation: At high magnetic field, degraded image quality due to dielectric artifacts and elevated SAR are two main technical challenges in fetal MRI at 3.0T. Goal(s): To assess the potential of HDC pad in increasing image quality and decreasing SAR in 3.0T fetal MRI. Approach: Quantitative Image-quality analysis included SNR and CNR. Qualitative analysis was performed by three radiologists with four-point scale to evaluate overall image quality, dielectric artifact and diagnostic confidence. Whole-body total SAR was read on software workstation. Results: With HDC pad, SNR and CNR was significantly higher while SAR was significantly lower. Impact: In clinical setting, adding HDC pad can increase overall quantitative and qualitative image quality while reducing dielectric artifact and SAR.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3615
Primary Topic
Fetal and Pediatric Neurological Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving image quality and decreasing SAR with high dielectric constant pad in 3.0T fetal MRI

Zengping Lin, Zhiying Zhu, Ye Li, Ming Li et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Fetal and Pediatric Neurological Disorders
article

Improving image quality and decreasing SAR with high dielectric constant pad in 3.0T fetal MRI

Zengping Lin, Zhiying Zhu, Ye Li, Ming Li, Chenchen Yan, Bing Zhang, Chao Luo, Tang Tang, Xiaobo Xue
article en

Abstract

Motivation: At high magnetic field, degraded image quality due to dielectric artifacts and elevated SAR are two main technical challenges in fetal MRI at 3.0T. Goal(s): To assess the potential of HDC pad in increasing image quality and decreasing SAR in 3.0T fetal MRI. Approach: Quantitative Image-quality analysis included SNR and CNR. Qualitative analysis was performed by three radiologists with four-point scale to evaluate overall image quality, dielectric artifact and diagnostic confidence. Whole-body total SAR was read on software workstation. Results: With HDC pad, SNR and CNR was significantly higher while SAR was significantly lower. Impact: In clinical setting, adding HDC pad can increase overall quantitative and qualitative image quality while reducing dielectric artifact and SAR.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Fetal and Pediatric Neurological Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.