Dynamic Perfusion Imaging of Dorsiflexion Exercise on Calf Muscles using a UTE-Based DW-SSFP Sequence

Motivation: The DW-SSFP sequence is very sensitive to perfusion due to a short echo time and 3- dimensional volume acquisition. Therefore, this sequence can be used for a dynamic perfusion study of muscles. Goal(s): Obtain a 3-dimensional exercise-induced perfusion map in a high sensitivity and fast temporal resolution. Approach: The DW-SSFP sequence was applied to measure the dynamic perfusion map of dorsiflexion exercise. Results: The dynamic change of perfusion was measured in 3-dimensional volume with a high sensitivity. Impact: The DW-SSFP sequence can detect the dynamic perfusion in 3-dimensions with a high sensitivity and fast temporal resolution. This sequence will be best for dynamic perfusion study compared to other methods such as ASL, BOLD, and EPI diffusion.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2963
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Perfusion Imaging of Dorsiflexion Exercise on Calf Muscles using a UTE-Based DW-SSFP Sequence

Kwan‐Jin Jung
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Dynamic Perfusion Imaging of Dorsiflexion Exercise on Calf Muscles using a UTE-Based DW-SSFP Sequence

Kwan‐Jin Jung
article en

Abstract

Motivation: The DW-SSFP sequence is very sensitive to perfusion due to a short echo time and 3- dimensional volume acquisition. Therefore, this sequence can be used for a dynamic perfusion study of muscles. Goal(s): Obtain a 3-dimensional exercise-induced perfusion map in a high sensitivity and fast temporal resolution. Approach: The DW-SSFP sequence was applied to measure the dynamic perfusion map of dorsiflexion exercise. Results: The dynamic change of perfusion was measured in 3-dimensional volume with a high sensitivity. Impact: The DW-SSFP sequence can detect the dynamic perfusion in 3-dimensions with a high sensitivity and fast temporal resolution. This sequence will be best for dynamic perfusion study compared to other methods such as ASL, BOLD, and EPI diffusion.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.