Comparison of gradient delay measurement and correction in diffusion-weighted 3D cones imaging in the breast

Motivation: Gradient delay correction must be carefully considered in non-cartesian imaging such as 3D cones to avoid severe artifacts. Goal(s): To compare in-vivo-based with phantom-based delay measurement and correction in diffusion-weighted 3D cones breast MRI. Approach: In 88 subjects, two blinded readers quality-ranked reconstructed images of double-echo steady-state diffusion-weighted breast MRI with three-dimensional cones using (i) no correction, (ii) in-vivo-based delay correction, and (iii) phantom-based delay correction. Results: Reconstructions with in-vivo-based correction were ranked best in only 40% of cases. Reconstructions done with phantom-based correction were ranked best in 89% of cases. Generally, in 94% of cases, correction led to improved image quality. Impact: In non-cartesian readouts, gradient delays cause artifacts. For diffusion-weighted breast MRI with a 3D cones trajectory, we show that retrospective delay correction based on in-vivo measurements requires further development to be considered a robust method.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3353
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of gradient delay measurement and correction in diffusion-weighted 3D cones imaging in the breast

Catherine J. Moran, Bruce L. Daniel, Brian A. Hargreaves, Judith Zimmermann et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
MRI in cancer diagnosis
article

Comparison of gradient delay measurement and correction in diffusion-weighted 3D cones imaging in the breast

Catherine J. Moran, Bruce L. Daniel, Brian A. Hargreaves, Judith Zimmermann, Kalina V. Jordanova, Xuetong Zhou
article en

Abstract

Motivation: Gradient delay correction must be carefully considered in non-cartesian imaging such as 3D cones to avoid severe artifacts. Goal(s): To compare in-vivo-based with phantom-based delay measurement and correction in diffusion-weighted 3D cones breast MRI. Approach: In 88 subjects, two blinded readers quality-ranked reconstructed images of double-echo steady-state diffusion-weighted breast MRI with three-dimensional cones using (i) no correction, (ii) in-vivo-based delay correction, and (iii) phantom-based delay correction. Results: Reconstructions with in-vivo-based correction were ranked best in only 40% of cases. Reconstructions done with phantom-based correction were ranked best in 89% of cases. Generally, in 94% of cases, correction led to improved image quality. Impact: In non-cartesian readouts, gradient delays cause artifacts. For diffusion-weighted breast MRI with a 3D cones trajectory, we show that retrospective delay correction based on in-vivo measurements requires further development to be considered a robust method.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
MRI in cancer diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of gradient delay measurement and correction in diffusion-weighted 3D cones imaging in the breast — Catherine J. Moran, Bruce L. Daniel, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS