Single breath-hold lung T2* mapping using multi-echo 3D spiral UTE with tight interval δTE

Motivation: Single-echo lung T2* mapping requires multiple images at different echo times, leading to long scan times and potential registration issues. While multi-echo sequences reduce scan time by acquiring multiple echoes in one shot, the echo intervals remain too long for lung short T2*. Goal(s): We aim to shorten the echo intervals within a single breath-hold to enable quantitative lung T2* mapping. Approach: We performed a segmented readout in the radial-spiral hybrid trajectory. Results: As a result, our proposed method enables single breath-hold (15 s) lung T2* quantification with an echo interval of 0.57 ms and in-plane resolution of 2 mm. Impact: Our proposed method enables single breath-hold lung T2* quantification with a 0.57 ms echo interval and 2 mm in-plane resolution. Rapid and accurate T2* assessment in the lungs is crucial for evaluating structural and functional changes caused by lung diseases.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3361
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single breath-hold lung T2* mapping using multi-echo 3D spiral UTE with tight interval δTE

Yupeng Cao, Jun Zhao, Weinan Tang, Dong Han et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Atomic and Subatomic Physics Research
article

Single breath-hold lung T2* mapping using multi-echo 3D spiral UTE with tight interval δTE

Yupeng Cao, Jun Zhao, Weinan Tang, Dong Han, Hongbin Wang, Hongjie Wang, Qian Zeng, Wentao Liu
article en

Abstract

Motivation: Single-echo lung T2* mapping requires multiple images at different echo times, leading to long scan times and potential registration issues. While multi-echo sequences reduce scan time by acquiring multiple echoes in one shot, the echo intervals remain too long for lung short T2*. Goal(s): We aim to shorten the echo intervals within a single breath-hold to enable quantitative lung T2* mapping. Approach: We performed a segmented readout in the radial-spiral hybrid trajectory. Results: As a result, our proposed method enables single breath-hold (15 s) lung T2* quantification with an echo interval of 0.57 ms and in-plane resolution of 2 mm. Impact: Our proposed method enables single breath-hold lung T2* quantification with a 0.57 ms echo interval and 2 mm in-plane resolution. Rapid and accurate T2* assessment in the lungs is crucial for evaluating structural and functional changes caused by lung diseases.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.