Multi b-value Distortion Correction for Ovarian Diffusion-Weighted MRI

Motivation: DW-MRI is now a standard sequence in ovarian MRI protocols. It is commonly implemented with Echo-Planar Imaging (EPI), which is prone to geometric distortions induced by static magnetic field (B0) inhomogeneities. Correcting distortion artifacts is important for anatomical and quantitative biomarker accuracy. Goal(s): To study multi b-value Reverse Polarity Gradient (mRPG) compared to commonly used RPG and FSL-topup. Approach: Pre-surgical ovarian MRI were collected and distortion corrected with the three methods. Results: mRPG showed better performance than RPG and topup in correcting EPI distortions in ADC maps, with less computational time. Impact: mRPG improves distortion artifacts compared to RPG and topup. It yields more accurate spatial and signal intensity corrections which are reflected in quantitative measures such as ADC, without significantly increasing scanning time and with shorter computational time.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0667
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi b-value Distortion Correction for Ovarian Diffusion-Weighted MRI

Rebecca Rakow‐Penner, Catherine J. Moran, Stéphane Loubrie, Hon Yu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
MRI in cancer diagnosis
article

Multi b-value Distortion Correction for Ovarian Diffusion-Weighted MRI

Rebecca Rakow‐Penner, Catherine J. Moran, Stéphane Loubrie, Hon Yu, Summer Batasin, Anders M. Dale, Christopher C. Conlin, Sheida Ebrahimi
article en

Abstract

Motivation: DW-MRI is now a standard sequence in ovarian MRI protocols. It is commonly implemented with Echo-Planar Imaging (EPI), which is prone to geometric distortions induced by static magnetic field (B0) inhomogeneities. Correcting distortion artifacts is important for anatomical and quantitative biomarker accuracy. Goal(s): To study multi b-value Reverse Polarity Gradient (mRPG) compared to commonly used RPG and FSL-topup. Approach: Pre-surgical ovarian MRI were collected and distortion corrected with the three methods. Results: mRPG showed better performance than RPG and topup in correcting EPI distortions in ADC maps, with less computational time. Impact: mRPG improves distortion artifacts compared to RPG and topup. It yields more accurate spatial and signal intensity corrections which are reflected in quantitative measures such as ADC, without significantly increasing scanning time and with shorter computational time.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
MRI in cancer diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.