Low acoustic noise scanning at 0.6T

Motivation: Patient comfort and well-being during the MRI scan are strongly influenced by the acoustic noise experienced during the MRI scan. At lower main magnetic field, lower Lorentz forces are encountered and therefore sound levels are lower compared to high-field MRI. Goal(s): Whisper level MRI without compromising image quality Approach: Gradient strength, scan parameters, and acceleration can be adjusted to achieve a sound level reduction of roughly 30dB compared to 1.5T for neuro and lumbar spine protocols. Results: Image quality of T1w, T2w, FLAIR, DWI and SWI is non-inferior standard protocols, all acquired in a total of 14 minutes for the neuro protocol. Impact: We show that acoustic noise at 0.6T can be reduced to very low levels with a relatively small increase in scan time and same image quality. This can drastically improve the patient experience.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0647
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low acoustic noise scanning at 0.6T

Martijn Nagtegaal, Matthias J.P. van Osch, Yiming Dong, Andrew Webb
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Ultrasonics and Acoustic Wave Propagation
article

Low acoustic noise scanning at 0.6T

Martijn Nagtegaal, Matthias J.P. van Osch, Yiming Dong, Andrew Webb
article en

Abstract

Motivation: Patient comfort and well-being during the MRI scan are strongly influenced by the acoustic noise experienced during the MRI scan. At lower main magnetic field, lower Lorentz forces are encountered and therefore sound levels are lower compared to high-field MRI. Goal(s): Whisper level MRI without compromising image quality Approach: Gradient strength, scan parameters, and acceleration can be adjusted to achieve a sound level reduction of roughly 30dB compared to 1.5T for neuro and lumbar spine protocols. Results: Image quality of T1w, T2w, FLAIR, DWI and SWI is non-inferior standard protocols, all acquired in a total of 14 minutes for the neuro protocol. Impact: We show that acoustic noise at 0.6T can be reduced to very low levels with a relatively small increase in scan time and same image quality. This can drastically improve the patient experience.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 72%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low acoustic noise scanning at 0.6T — Martijn Nagtegaal, Matthias J.P. van Osch, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS