Distortion Correction in TSE Near Metal Implants at 0.55T Using Model-Based Iterative Reconstruction and Opposite Readout Acquisitions

Motivation: View angle tilting for reducing signal displacement artifacts near metal is difficult to adopt at 0.55T due to blurring and decreased SNR due to high readout bandwidth. Goal(s): To develop a method that corrects in-plane displacement artifacts near metal implants at 0.55T, achieving higher SNR without sacrificing image sharpness. Approach: TSE acquisitions with opposite frequency-encoding directions were performed. Gradient nonlinearity-corrected images were first generated. Displacement maps were estimated by TOPUP from the GNL-corrected images. Final images were reconstructed using Type-1 NUFFT-based CG-SENSE by incorporating both GNL and TOPUP-derived displacement fields. Results: The proposed method, performed without VAT, eliminated blurring and achieved superior SNR. Impact: This method enhances SNR without blurring for MRI near metal implants at 0.55T, benefiting low-SNR regions such as the spine and disc, while avoiding the prolonged scan times associated with VAT methods that require multiple averages for SNR improvement.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0640
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distortion Correction in TSE Near Metal Implants at 0.55T Using Model-Based Iterative Reconstruction and Opposite Readout Acquisitions

Alexander Toews, Kübra Keskin, Daehyun Yoon, Krishna S. Nayak et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced X-ray and CT Imaging
article

Distortion Correction in TSE Near Metal Implants at 0.55T Using Model-Based Iterative Reconstruction and Opposite Readout Acquisitions

Alexander Toews, Kübra Keskin, Daehyun Yoon, Krishna S. Nayak, Bochao Li, Jay Acharya, Nam Lee, Jordan S. Gross, Brian Hargreaves
article en

Abstract

Motivation: View angle tilting for reducing signal displacement artifacts near metal is difficult to adopt at 0.55T due to blurring and decreased SNR due to high readout bandwidth. Goal(s): To develop a method that corrects in-plane displacement artifacts near metal implants at 0.55T, achieving higher SNR without sacrificing image sharpness. Approach: TSE acquisitions with opposite frequency-encoding directions were performed. Gradient nonlinearity-corrected images were first generated. Displacement maps were estimated by TOPUP from the GNL-corrected images. Final images were reconstructed using Type-1 NUFFT-based CG-SENSE by incorporating both GNL and TOPUP-derived displacement fields. Results: The proposed method, performed without VAT, eliminated blurring and achieved superior SNR. Impact: This method enhances SNR without blurring for MRI near metal implants at 0.55T, benefiting low-SNR regions such as the spine and disc, while avoiding the prolonged scan times associated with VAT methods that require multiple averages for SNR improvement.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.