Outer-Volume Suppressed Accelerated CMR via Static Tissue Subtraction

Motivation: CMR cine and perfusion imaging have redundant static regions, requiring a large FOV to prevent aliasing onto the heart, reducing efficiency. Goal(s): Create a post-processing method to reduce static tissue effects, enabling faster CMR imaging with standard reconstruction techniques and no outer volume suppression pulses. Approach: For breath-held CMR, we isolate the static tissue signal from averaged or separate data and subtract it from each k-space measurement. This allows for an enhanced per-frame reconstruction. Results: Achieved up to 9.39 dB SNR improvement in cine images and removed static tissue overlapping in SMILE perfusion (multiband factor = 6) without suppression pulses. Impact: This technique can be applied to other dynamic CMR applications with a largely static FOV region. It eliminates the need for outer volume suppression, enhancing acquisition efficiency with a reduced FOV and supporting higher acceleration rates in reconstruction.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3366
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Outer-Volume Suppressed Accelerated CMR via Static Tissue Subtraction

Sizhuo Liu, Michael Salerno, Shen Zhao, Quan Chen et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Dental Implant Techniques and Outcomes
article

Outer-Volume Suppressed Accelerated CMR via Static Tissue Subtraction

Sizhuo Liu, Michael Salerno, Shen Zhao, Quan Chen, Xitong Wang
article en

Abstract

Motivation: CMR cine and perfusion imaging have redundant static regions, requiring a large FOV to prevent aliasing onto the heart, reducing efficiency. Goal(s): Create a post-processing method to reduce static tissue effects, enabling faster CMR imaging with standard reconstruction techniques and no outer volume suppression pulses. Approach: For breath-held CMR, we isolate the static tissue signal from averaged or separate data and subtract it from each k-space measurement. This allows for an enhanced per-frame reconstruction. Results: Achieved up to 9.39 dB SNR improvement in cine images and removed static tissue overlapping in SMILE perfusion (multiband factor = 6) without suppression pulses. Impact: This technique can be applied to other dynamic CMR applications with a largely static FOV region. It eliminates the need for outer volume suppression, enhancing acquisition efficiency with a reduced FOV and supporting higher acceleration rates in reconstruction.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.