Correction of time-dependent phase fluctuations in diffusion-weighted MRS at high b-values with external phantom reference

Motivation: Diffusion-weighted MRS (dMRS) generates field fluctuations that distort spectral line shapes. Traditional water reference scans can be noisy at high b-values and fail to correct the spectra. Goal(s): This study aims to (1) map field fluctuations, (2) develop a stable phantom reference, (3) validate it against water scans in high-b-value acquisitions, and (4) extract diffusion properties. Approach: Spatial field fluctuations were mapped with a high-viscosity silicone oil phantom, and its performance in phase correction was compared to water reference scans in simulations and invivo. Results: The phantom reference was used to successfully correct invivo dMRS data up to a b-value of 37 ms/μm². Impact: This research can help improve dMRS data quality at high b-values by correcting signal distortions with a phantom reference scan. This reduces scanning time in human studies and makes dMRS more practical for clinical use.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4076
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correction of time-dependent phase fluctuations in diffusion-weighted MRS at high b-values with external phantom reference

Henrik Lundell, Vanessa Wiggermann, Itamar Ronen, K. Engel
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Neuroimaging Techniques and Applications
article

Correction of time-dependent phase fluctuations in diffusion-weighted MRS at high b-values with external phantom reference

Henrik Lundell, Vanessa Wiggermann, Itamar Ronen, K. Engel
article en

Abstract

Motivation: Diffusion-weighted MRS (dMRS) generates field fluctuations that distort spectral line shapes. Traditional water reference scans can be noisy at high b-values and fail to correct the spectra. Goal(s): This study aims to (1) map field fluctuations, (2) develop a stable phantom reference, (3) validate it against water scans in high-b-value acquisitions, and (4) extract diffusion properties. Approach: Spatial field fluctuations were mapped with a high-viscosity silicone oil phantom, and its performance in phase correction was compared to water reference scans in simulations and invivo. Results: The phantom reference was used to successfully correct invivo dMRS data up to a b-value of 37 ms/μm². Impact: This research can help improve dMRS data quality at high b-values by correcting signal distortions with a phantom reference scan. This reduces scanning time in human studies and makes dMRS more practical for clinical use.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.