Velocity-selective continuous arterial spin labeling

Motivation: Velocity-selective arterial spin labeling (VSASL) addresses transit delay errors of conventional ASL methods, but suffers from a lower signal-to-noise ratio (SNR) than standard pseudocontinuous ASL (PCASL). Goal(s): To develop velocity-selective continuous ASL (VS-CASL) for improved SNR with the removed transit delay. Approach: A delay alternating with nutation for tailored excitation (DANTE) pulse was applied immediately after global saturation to maintain the magnetization of flowing spins at a very low level until these spins decelerate below a cutoff velocity, serving as velocity-selective continuous labeling. Results: The proposed approach of VS-CASL demonstrated a similar contrast to other ASL methods with increased SNR. Impact: This work demonstrated a novel approach to ASL perfusion imaging, combining the advantages of VSASL and PCASL, and showing the potential to eliminate transit delay and enhance SNR.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3700
Primary Topic
Lanthanide and Transition Metal Complexes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Velocity-selective continuous arterial spin labeling

Zungho Zun
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Lanthanide and Transition Metal Complexes
article

Velocity-selective continuous arterial spin labeling

Zungho Zun
article en

Abstract

Motivation: Velocity-selective arterial spin labeling (VSASL) addresses transit delay errors of conventional ASL methods, but suffers from a lower signal-to-noise ratio (SNR) than standard pseudocontinuous ASL (PCASL). Goal(s): To develop velocity-selective continuous ASL (VS-CASL) for improved SNR with the removed transit delay. Approach: A delay alternating with nutation for tailored excitation (DANTE) pulse was applied immediately after global saturation to maintain the magnetization of flowing spins at a very low level until these spins decelerate below a cutoff velocity, serving as velocity-selective continuous labeling. Results: The proposed approach of VS-CASL demonstrated a similar contrast to other ASL methods with increased SNR. Impact: This work demonstrated a novel approach to ASL perfusion imaging, combining the advantages of VSASL and PCASL, and showing the potential to eliminate transit delay and enhance SNR.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Lanthanide and Transition Metal Complexes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Velocity-selective continuous arterial spin labeling — Zungho Zun · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS