DeepEddy: high-quality fast eddy current and bulk motion correction using deep learning-based image synthesis and co-registration

Motivation: FSL's "Eddy" function accurately corrects eddy currents and bulk motion in diffusion data but requires 16 diffusion directions or more. Goal(s): Develop a deep learning-based correction method with Eddy-level performance without the diffusion direction sampling requirement. Approach: Our proposed DeepEddy pipeline 1) converts each diffusion-weighted image (DWI) into a b=0 image; 2) nonlinearly co-registers the synthesized and empirical b=0 images; 3) applies derived warp fields to original correspondence DWIs. Results: DeepEddy reduces diffusion volumes variance, improves diffusion metrics, and achieves Eddy-level performance without the diffusion direction sampling requirement. Impact: DeepEddy enables eddy current and bulk motion correction for diffusion data with any number of diffusion directions, showing the promise to benefit clinical applications where scan time is extremely limited.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0746
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DeepEddy: high-quality fast eddy current and bulk motion correction using deep learning-based image synthesis and co-registration

Mingxuan Liu, Frederik Lange, Qiyuan Tian, J. Zhang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Non-Destructive Testing Techniques
article

DeepEddy: high-quality fast eddy current and bulk motion correction using deep learning-based image synthesis and co-registration

Mingxuan Liu, Frederik Lange, Qiyuan Tian, J. Zhang, Jesper Andersson, Wenchuan Wu, Ziyu Li, Jing Yi, Zihan Li, Jialan Zheng, Hongjia Yang
article en

Abstract

Motivation: FSL's "Eddy" function accurately corrects eddy currents and bulk motion in diffusion data but requires 16 diffusion directions or more. Goal(s): Develop a deep learning-based correction method with Eddy-level performance without the diffusion direction sampling requirement. Approach: Our proposed DeepEddy pipeline 1) converts each diffusion-weighted image (DWI) into a b=0 image; 2) nonlinearly co-registers the synthesized and empirical b=0 images; 3) applies derived warp fields to original correspondence DWIs. Results: DeepEddy reduces diffusion volumes variance, improves diffusion metrics, and achieves Eddy-level performance without the diffusion direction sampling requirement. Impact: DeepEddy enables eddy current and bulk motion correction for diffusion data with any number of diffusion directions, showing the promise to benefit clinical applications where scan time is extremely limited.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 75%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.