Joint reconstruction and motion correction of the fetal brain T2 maps

Motivation: Our previously proposed pipeline for measuring T2 involves obtaining three stacks at three echo times (TE), totalling nine stacks, to produce 3D motion-corrected T2 maps. Here, we propose updates to streamline the process, reduce data requirements, and improve the usability of the previous pipeline. Goal(s): Update the pipeline to jointly reconstruct all the stacks together to directly produce a T2 map. Approach: Reconstruct a multi-channel volume from all the stacks to which a dictionary is fitted to generate the T2 map. Validate the method on a simulated phantom. Results: We find that the update improves robustness to motion and reduces data requirement. Impact: This should improve the usability of the previously proposed T2 measurement pipeline and allow for faster scan times as less data is required as well as improve robustness to motion when all nine stacks are used.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4441
Primary Topic
Fetal and Pediatric Neurological Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Joint reconstruction and motion correction of the fetal brain T2 maps

Lucilio Cordero‐Grande, Suryava Bhattacharya, Shaihan Malik, Maria Deprez et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Fetal and Pediatric Neurological Disorders
article

Joint reconstruction and motion correction of the fetal brain T2 maps

Lucilio Cordero‐Grande, Suryava Bhattacharya, Shaihan Malik, Maria Deprez, Massimo Marenzana, Alena Uus, Anthony N. Price, Helena S. Sousa, Kathleen Colford, Maggie Lee
article en

Abstract

Motivation: Our previously proposed pipeline for measuring T2 involves obtaining three stacks at three echo times (TE), totalling nine stacks, to produce 3D motion-corrected T2 maps. Here, we propose updates to streamline the process, reduce data requirements, and improve the usability of the previous pipeline. Goal(s): Update the pipeline to jointly reconstruct all the stacks together to directly produce a T2 map. Approach: Reconstruct a multi-channel volume from all the stacks to which a dictionary is fitted to generate the T2 map. Validate the method on a simulated phantom. Results: We find that the update improves robustness to motion and reduces data requirement. Impact: This should improve the usability of the previously proposed T2 measurement pipeline and allow for faster scan times as less data is required as well as improve robustness to motion when all nine stacks are used.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Fetal and Pediatric Neurological Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.