An Explainable AI-based Motion Detection approach for MR images without requirement of motion annotated ground truth data

Motivation: Motion is one of the leading causes of artifacts in MR images. Such images are often rendered non-diagnostic, and results in patient recall. Goal(s): Objective is to detect motion in MRI scans and provide information on extent of motion so that MRI technologists can decide on whether to re-scan the subject. Approach: The proposed AI-based method detects motion in MR images and provides a motion severity score, while not relying on real world annotated motion data. Results: The proposed method was tested on a set of real-world MRI data with and without motion and provided an accuracy of 89.6%. Impact: Reliable motion alert for MRI scans shall enable technologists to re-scan the subjects while in the scanning room. This will help in reducing the patient recalls due to motion artifact and hence reduce burden on the healthcare system.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0744
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Explainable AI-based Motion Detection approach for MR images without requirement of motion annotated ground truth data

Subhashis Banerjee, Sudhanya Chatterjee, Dattesh Shanbhag
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Imaging and Analysis
article

An Explainable AI-based Motion Detection approach for MR images without requirement of motion annotated ground truth data

Subhashis Banerjee, Sudhanya Chatterjee, Dattesh Shanbhag
article en

Abstract

Motivation: Motion is one of the leading causes of artifacts in MR images. Such images are often rendered non-diagnostic, and results in patient recall. Goal(s): Objective is to detect motion in MRI scans and provide information on extent of motion so that MRI technologists can decide on whether to re-scan the subject. Approach: The proposed AI-based method detects motion in MR images and provides a motion severity score, while not relying on real world annotated motion data. Results: The proposed method was tested on a set of real-world MRI data with and without motion and provided an accuracy of 89.6%. Impact: Reliable motion alert for MRI scans shall enable technologists to re-scan the subjects while in the scanning room. This will help in reducing the patient recalls due to motion artifact and hence reduce burden on the healthcare system.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.