Applying NORDIC denoising to high-resolution T1-mapping for structural layer measures

Motivation: High resolution T1-mapping can become SNR limited and be highly sensitive to spatial SNR drop-offs when using surface receive coil arrays. This results in poor T1 fits and segmentations which in turn impacts layer-specific structural measures. Goal(s): To apply NORDIC denoising to T1-mapping data to assess how it impacts structural layer measures. Approach: High resolution T1-mapping data collected using a surface coil array. NORDIC denoising applied at multiple patch sizes. Resultant T1 and R2 maps, segmentation and cortical depth profiles compared. Results: NORDIC denoising provides visual improvements in T1-maps with improving R2 of the fit. However, smaller NORDIC patch sizes introduce smoothing. Impact: NORDIC denoising improves quantitative high-resolution brain T1-mapping for structural measures collected alongside layer fMRI and is beneficial for segmentation of data acquired on surface receive coils. It is important to consider smoothing introduced by smaller NORDIC patch sizes.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3419
Primary Topic
Seismic Imaging and Inversion Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applying NORDIC denoising to high-resolution T1-mapping for structural layer measures

Agatha Lenartowicz, D. R. Marsh, Michael Asghar, Susan Francis et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Seismic Imaging and Inversion Techniques
article

Applying NORDIC denoising to high-resolution T1-mapping for structural layer measures

Agatha Lenartowicz, D. R. Marsh, Michael Asghar, Susan Francis, Karen J. Mullinger
article en

Abstract

Motivation: High resolution T1-mapping can become SNR limited and be highly sensitive to spatial SNR drop-offs when using surface receive coil arrays. This results in poor T1 fits and segmentations which in turn impacts layer-specific structural measures. Goal(s): To apply NORDIC denoising to T1-mapping data to assess how it impacts structural layer measures. Approach: High resolution T1-mapping data collected using a surface coil array. NORDIC denoising applied at multiple patch sizes. Resultant T1 and R2 maps, segmentation and cortical depth profiles compared. Results: NORDIC denoising provides visual improvements in T1-maps with improving R2 of the fit. However, smaller NORDIC patch sizes introduce smoothing. Impact: NORDIC denoising improves quantitative high-resolution brain T1-mapping for structural measures collected alongside layer fMRI and is beneficial for segmentation of data acquired on surface receive coils. It is important to consider smoothing introduced by smaller NORDIC patch sizes.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 74%
Seismic Imaging and Inversion Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.