Quiet ASL with Non-rephasing Labeling Gradients and Silent Readout

Motivation: ASL has been used in pediatric perfusion imaging and resting-state fMRI studies. However, the recommended pCASL sequences generate acoustic noise because of the maximum slew rate employed in the labeling and acquisition parts. Goal(s): To develop a pCASL sequence with reduced acoustic noise. Approach: Paired triangle-shape gradients without rephasing gradients was proposed to provide pseudo continuous arterial labeling and the WASPI readout, instead of GRASE, was optimized for ASL acquisition. Results: The proposed quiet pCASL sequence reduced acoustic noise by 47% in the labeling part and 96% in the acquisition part while maintaining competitive image quality compared to conventional pCASL. Impact: The proposed quiet ASL provided a novel approach to label blood. It may improve patients experience and have a great potential in resting state fMRI studies.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0733
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quiet ASL with Non-rephasing Labeling Gradients and Silent Readout

Jichang Zhang, Jiaxin Li, Li Zhao, Erliang Zheng
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Photonic and Optical Devices
article

Quiet ASL with Non-rephasing Labeling Gradients and Silent Readout

Jichang Zhang, Jiaxin Li, Li Zhao, Erliang Zheng
article en

Abstract

Motivation: ASL has been used in pediatric perfusion imaging and resting-state fMRI studies. However, the recommended pCASL sequences generate acoustic noise because of the maximum slew rate employed in the labeling and acquisition parts. Goal(s): To develop a pCASL sequence with reduced acoustic noise. Approach: Paired triangle-shape gradients without rephasing gradients was proposed to provide pseudo continuous arterial labeling and the WASPI readout, instead of GRASE, was optimized for ASL acquisition. Results: The proposed quiet pCASL sequence reduced acoustic noise by 47% in the labeling part and 96% in the acquisition part while maintaining competitive image quality compared to conventional pCASL. Impact: The proposed quiet ASL provided a novel approach to label blood. It may improve patients experience and have a great potential in resting state fMRI studies.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quiet ASL with Non-rephasing Labeling Gradients and Silent Readout — Jichang Zhang, Jiaxin Li, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS