Optimizing the white matter/grey matter contrast on a portable 46 mT MRI scanner

Motivation: Low-field MRI, known for its accessibility and portability, faces challenges in distinguishing grey matter (GM) from white matter (WM) due to lower signal-to-noise ratios and converging relaxation times. Goal(s): This study aimed to improve WM/GM contrast in low-field MRI using a T1-weighted sequence with short inversion time (TI). Approach: T1-weighted sequence with optimized TI (90ms) was used to enhance contrast maintaining good SNR. Other TIs and resolution were also tested. Results: Results showed consistently high WM/GM contrast across subjects and resolution, with an optimal TI of 90 ms balancing contrast and SNR. Impact: This study demonstrates that a T1-weighted sequence with optimized inversion time effectively enhances grey-to-white matter contrast in low-field MRI, offering reliable tissue differentiation for different subjects and resolutions.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4238
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing the white matter/grey matter contrast on a portable 46 mT MRI scanner

Beatrice Lena, Chloé Najac, Thomas O’Reilly, Andrew Webb et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Optimizing the white matter/grey matter contrast on a portable 46 mT MRI scanner

Beatrice Lena, Chloé Najac, Thomas O’Reilly, Andrew Webb, Ruben van den Broek
article en

Abstract

Motivation: Low-field MRI, known for its accessibility and portability, faces challenges in distinguishing grey matter (GM) from white matter (WM) due to lower signal-to-noise ratios and converging relaxation times. Goal(s): This study aimed to improve WM/GM contrast in low-field MRI using a T1-weighted sequence with short inversion time (TI). Approach: T1-weighted sequence with optimized TI (90ms) was used to enhance contrast maintaining good SNR. Other TIs and resolution were also tested. Results: Results showed consistently high WM/GM contrast across subjects and resolution, with an optimal TI of 90 ms balancing contrast and SNR. Impact: This study demonstrates that a T1-weighted sequence with optimized inversion time effectively enhances grey-to-white matter contrast in low-field MRI, offering reliable tissue differentiation for different subjects and resolutions.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.