Preclinical ¹H MRS at Ultra-High Field: A Comparative Study of LASER and STEAM Sequences in Mouse Brain

Motivation: At ultra-high magnetic fields (UHF), shortened T₂ relaxation times of water and metabolites necessitate efficient magnetic resonance spectroscopy (MRS) sequences like STEAM and LASER. Goal(s): To compare the neurochemical profiles obtained using LASER and STEAM sequences in the mouse brain at 11.7 T. Approach: Short echo-time LASER (TE = 16.75 ms) and STEAM (TE/TM = 2.7/10 ms) MRS data were acquired from the caudate-putamen region in nine adult female C57BL/6 mice. Results: Neurochemical profiles from both sequences were highly correlated (r = 0.97), with LASER showing a twofold increase in SNR compared to STEAM. Impact: LASER's higher SNR can reduce scan time in preclinical studies at UHF, enabling more efficient data acquisition and facilitating advanced applications like dynamic MRS and neurochemical profiling of smaller brain structures.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0841
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preclinical ¹H MRS at Ultra-High Field: A Comparative Study of LASER and STEAM Sequences in Mouse Brain

Alireza Abaei, Francesco Roselli, Volker Rasche, Dinesh K. Deelchand
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Preclinical ¹H MRS at Ultra-High Field: A Comparative Study of LASER and STEAM Sequences in Mouse Brain

Alireza Abaei, Francesco Roselli, Volker Rasche, Dinesh K. Deelchand
article en

Abstract

Motivation: At ultra-high magnetic fields (UHF), shortened T₂ relaxation times of water and metabolites necessitate efficient magnetic resonance spectroscopy (MRS) sequences like STEAM and LASER. Goal(s): To compare the neurochemical profiles obtained using LASER and STEAM sequences in the mouse brain at 11.7 T. Approach: Short echo-time LASER (TE = 16.75 ms) and STEAM (TE/TM = 2.7/10 ms) MRS data were acquired from the caudate-putamen region in nine adult female C57BL/6 mice. Results: Neurochemical profiles from both sequences were highly correlated (r = 0.97), with LASER showing a twofold increase in SNR compared to STEAM. Impact: LASER's higher SNR can reduce scan time in preclinical studies at UHF, enabling more efficient data acquisition and facilitating advanced applications like dynamic MRS and neurochemical profiling of smaller brain structures.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.