Head motion correction based on Pilot Tone signals – a referenceless method

Motivation: Motion remains a problem in clinical MRI largely because all existing effective methods come with a penalty, whether constraints on pulse sequences, expensive/bulky equipment, or extra steps in the workflow. Goal(s): To develop a motion correction method that is effective yet highly practical. Approach: A new model was developed based on Pilot Tone signals, to achieve sizable reductions in motion artifacts. The approach shares the burden of motion correction between sensors (Pilot Tone) and software (iterative reconstruction). Results: As tested in nineteen motion scans in four volunteers, the proposed approach is effective at suppressing motion artifacts, at little to no impact on workflow. Impact: The proposed approach is effective at reducing motion artifacts, and it was designed to be translatable to clinical practice, as it does not affect workflow.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4429
Primary Topic
Speech and Audio Processing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Head motion correction based on Pilot Tone signals – a referenceless method

Jeffrey P. Guenette, Jayant Dubey, Qin Lei, Bruno Madore et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Speech and Audio Processing
article

Head motion correction based on Pilot Tone signals – a referenceless method

Jeffrey P. Guenette, Jayant Dubey, Qin Lei, Bruno Madore, Cheng‐Chieh Cheng, Yajun Li
article en

Abstract

Motivation: Motion remains a problem in clinical MRI largely because all existing effective methods come with a penalty, whether constraints on pulse sequences, expensive/bulky equipment, or extra steps in the workflow. Goal(s): To develop a motion correction method that is effective yet highly practical. Approach: A new model was developed based on Pilot Tone signals, to achieve sizable reductions in motion artifacts. The approach shares the burden of motion correction between sensors (Pilot Tone) and software (iterative reconstruction). Results: As tested in nineteen motion scans in four volunteers, the proposed approach is effective at suppressing motion artifacts, at little to no impact on workflow. Impact: The proposed approach is effective at reducing motion artifacts, and it was designed to be translatable to clinical practice, as it does not affect workflow.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 69%
Speech and Audio Processing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.