Can spleen T1 mapping be used as a marker of adequate adenosine response in stress perfusion CMR?

Motivation: There is limited existing data regarding T1 mapping as a method for assessing splenic switch-off. Goal(s): To further investigate quantitative T1 mapping for splenic switch-off assessment as a marker of adequate response to adenosine in stress in CMR perfusion studies for improving test accuracy and mitigating the occurrence of false-negatives. Approach: Prospective CMR with first-pass perfusion and T1 mapping at rest and stress in 59 patients at 1.5T. Results: Splenic T1 values decreased from rest to stress in patients with switch-off. T1 mapping detected splenic switch-off in a clinical population with a specificity of 75% and sensitivity of 80% (ΔT1 threshold of -5.5ms). Impact: This study suggest that splenic T1 changes can detect splenic switch-off during adenosine stress CMR, potentially enabling real-time stress adequacy assessment. However, it raises questions about adenosine's effects on splenic perfusion and the link of splenic switch-off to myocardial response.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4338
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can spleen T1 mapping be used as a marker of adequate adenosine response in stress perfusion CMR?

María A. Fernández‐Seara, Gorka Bastarrika, Sergio Solis-Barquero, Marina Pascual et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Ultrasound and Hyperthermia Applications
article

Can spleen T1 mapping be used as a marker of adequate adenosine response in stress perfusion CMR?

María A. Fernández‐Seara, Gorka Bastarrika, Sergio Solis-Barquero, Marina Pascual, Verónica Aramendía‐Vidaurreta, Ana Ezponda, Marta Vidorreta
article en

Abstract

Motivation: There is limited existing data regarding T1 mapping as a method for assessing splenic switch-off. Goal(s): To further investigate quantitative T1 mapping for splenic switch-off assessment as a marker of adequate response to adenosine in stress in CMR perfusion studies for improving test accuracy and mitigating the occurrence of false-negatives. Approach: Prospective CMR with first-pass perfusion and T1 mapping at rest and stress in 59 patients at 1.5T. Results: Splenic T1 values decreased from rest to stress in patients with switch-off. T1 mapping detected splenic switch-off in a clinical population with a specificity of 75% and sensitivity of 80% (ΔT1 threshold of -5.5ms). Impact: This study suggest that splenic T1 changes can detect splenic switch-off during adenosine stress CMR, potentially enabling real-time stress adequacy assessment. However, it raises questions about adenosine's effects on splenic perfusion and the link of splenic switch-off to myocardial response.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Can spleen T1 mapping be used as a marker of adequate adenosine response in stress perfusion CMR? — María A. Fernández‐Seara, Gorka Bastarrika, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS