Coil evaluation for abdominal imaging of hyperpolarized 13C-pyruvate

Motivation: Clamshell coils are widely used for hyperpolarized 13C-MRI but have limitations in obesity and with widely disseminated disease. Goal(s): To evaluate a 4-rung birdcage in conjunction with 2 receive arrays (25 total channels) with ~50cm coverage. Approach: Artifacts, SNR and noise correlations were evaluated using phantoms and the performance of the hardware was shown in a hyperpolarized [1-13C]pyruvate volunteer examination. Results: The transmit efficiency was acceptable, albeit less when the receive arrays were present, and sporadic spikes were observed. The receive arrays showed SNR benefits relative to birdcage T/R and to previous configurations. Good images were obtained in vivo. Impact: This body multi-channel array setup enables 13C studies of diseases which may otherwise not be evaluable with clamshell coils. For example, ovarian cancer is widely disseminated through the abdomen and obesity is a strong risk factor.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4991
Primary Topic
Advanced NMR Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coil evaluation for abdominal imaging of hyperpolarized 13C-pyruvate

Elizabeth Latimer, Mary A. McLean, Titus Lanz, Ines Horvat‐Menih et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced NMR Techniques and Applications
article

Coil evaluation for abdominal imaging of hyperpolarized 13C-pyruvate

Elizabeth Latimer, Mary A. McLean, Titus Lanz, Ines Horvat‐Menih, Ferdia A. Gallagher, Fraser Robb, Marta Wylot, Jonathan R. Birchall, Joshua Kaggie, A. B. Morris, Martin J. Graves, Ashley Grimmer, Maria Jesus Zamora Morales
article en

Abstract

Motivation: Clamshell coils are widely used for hyperpolarized 13C-MRI but have limitations in obesity and with widely disseminated disease. Goal(s): To evaluate a 4-rung birdcage in conjunction with 2 receive arrays (25 total channels) with ~50cm coverage. Approach: Artifacts, SNR and noise correlations were evaluated using phantoms and the performance of the hardware was shown in a hyperpolarized [1-13C]pyruvate volunteer examination. Results: The transmit efficiency was acceptable, albeit less when the receive arrays were present, and sporadic spikes were observed. The receive arrays showed SNR benefits relative to birdcage T/R and to previous configurations. Good images were obtained in vivo. Impact: This body multi-channel array setup enables 13C studies of diseases which may otherwise not be evaluable with clamshell coils. For example, ovarian cancer is widely disseminated through the abdomen and obesity is a strong risk factor.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 77%
Advanced NMR Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.