E-field Simulation in Human Body Models for High Performance Non-Whole-Body Gradient Coil IEC Cardiac Stimulation Compliance

Motivation: IEC60601-2-33 standard does not provide guidance on cardiac stimulation (CS) compliance for a non-whole-body (NWB) gradient coil (GC) and E-field estimation cannot be easily obtained via direct measurement on humans. Goal(s): Discuss how E-field simulation with human models can be used to obtain conservative and solid electric field strength in the heart generated by GC. Approach: Sim4Life FEM QS solver is used to calculate E-field in the heart of 7 human body models in MAGNUS GC. Numerical error handling and reduction are discussed. Results: FEM simulation with IEEE C95.1 smoothing method can provide conservative E-field estimation in the heart. Impact: CS compliance for a NWB GC has not been widely discussed even though it is a key safety criterion. This work shows the feasibility of simulation-based CS risk assessment in a high-performance head GC.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1328
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

E-field Simulation in Human Body Models for High Performance Non-Whole-Body Gradient Coil IEC Cardiac Stimulation Compliance

Thomas Foo, Sayım Gökyar, Seung‐Kyun Lee, Desmond Yeo et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Neuroscience and Neural Engineering
article

E-field Simulation in Human Body Models for High Performance Non-Whole-Body Gradient Coil IEC Cardiac Stimulation Compliance

Thomas Foo, Sayım Gökyar, Seung‐Kyun Lee, Desmond Yeo, Yihe Hua
article en

Abstract

Motivation: IEC60601-2-33 standard does not provide guidance on cardiac stimulation (CS) compliance for a non-whole-body (NWB) gradient coil (GC) and E-field estimation cannot be easily obtained via direct measurement on humans. Goal(s): Discuss how E-field simulation with human models can be used to obtain conservative and solid electric field strength in the heart generated by GC. Approach: Sim4Life FEM QS solver is used to calculate E-field in the heart of 7 human body models in MAGNUS GC. Numerical error handling and reduction are discussed. Results: FEM simulation with IEEE C95.1 smoothing method can provide conservative E-field estimation in the heart. Impact: CS compliance for a NWB GC has not been widely discussed even though it is a key safety criterion. This work shows the feasibility of simulation-based CS risk assessment in a high-performance head GC.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 73%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.