Exploring feasibility of whole-brain arterial spin labeling in 10 seconds

Motivation: Arterial spin labeling (ASL) typically requires repeated measurements due to low SNR and/or transit delay sensitivity, resulting in long scan time. Goal(s): To explore the feasibility of ASL measurement with a single-repetition. Approach: To take advantage of recent technical advances, deep learning denoising and velocity-selective ASL approaches are combined to explore the feasibility of obtaining reliable perfusion measurement with considerable less scan time, in the extreme case, using one single repetition of ASL scan. Results: Our preliminary results demonstrated the feasible of whole-brain ASL measurement with a single repetition. This new method will be investigated further. Impact: The method proposed in this study will enable accurate ASL perfusion measurement with significant reduction of scan time, making ASL potentially an additional diagnostic tool in acute perfusion imaging applications where scan time is extremely precious.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3702
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring feasibility of whole-brain arterial spin labeling in 10 seconds

Naveed Ilyas, Jia Guo
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Exploring feasibility of whole-brain arterial spin labeling in 10 seconds

Naveed Ilyas, Jia Guo
article en

Abstract

Motivation: Arterial spin labeling (ASL) typically requires repeated measurements due to low SNR and/or transit delay sensitivity, resulting in long scan time. Goal(s): To explore the feasibility of ASL measurement with a single-repetition. Approach: To take advantage of recent technical advances, deep learning denoising and velocity-selective ASL approaches are combined to explore the feasibility of obtaining reliable perfusion measurement with considerable less scan time, in the extreme case, using one single repetition of ASL scan. Results: Our preliminary results demonstrated the feasible of whole-brain ASL measurement with a single repetition. This new method will be investigated further. Impact: The method proposed in this study will enable accurate ASL perfusion measurement with significant reduction of scan time, making ASL potentially an additional diagnostic tool in acute perfusion imaging applications where scan time is extremely precious.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.