Quantitative Ultrashort T2 Components Imaging using Variable Flip Angle Balanced Steady State Free Precession Ultrashort Echo Time MRI

Motivation: The current UTE-based myelin quantification method requires multiple TEs acquisitions, which has disadvantages include long scan time, complicated fitting models with too many unknown parameters to be fit. Goal(s): To propose a simplified fitting model to quantify myelin fraction. Approach: Previously developed dual-echo bSSFP UTE sequence with variable flip angles was applied. The difference of the signal curve along flip angles between first and second TE was used to quantify T1 and fraction values of myelin. Multiple sclerosis patients were recruited and tested. Results: The overall myelin T1 values are around 80 to 200 ms, and the uT2 fraction is around 10-20%. Impact: This new UTE-based method used simplified model to provide reliable fitting results of uT2 fraction, which was also tested on multiple sclerosis patients, could aid in future multiple sclerosis diagnosis and evaluation of re-myelination during treatment.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1494
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Ultrashort T2 Components Imaging using Variable Flip Angle Balanced Steady State Free Precession Ultrashort Echo Time MRI

Uzay E. Emir, Xin Shen, Ari Green, Peder E. Z. Larson et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Quantitative Ultrashort T2 Components Imaging using Variable Flip Angle Balanced Steady State Free Precession Ultrashort Echo Time MRI

Uzay E. Emir, Xin Shen, Ari Green, Peder E. Z. Larson, Roland G. Henry
article en

Abstract

Motivation: The current UTE-based myelin quantification method requires multiple TEs acquisitions, which has disadvantages include long scan time, complicated fitting models with too many unknown parameters to be fit. Goal(s): To propose a simplified fitting model to quantify myelin fraction. Approach: Previously developed dual-echo bSSFP UTE sequence with variable flip angles was applied. The difference of the signal curve along flip angles between first and second TE was used to quantify T1 and fraction values of myelin. Multiple sclerosis patients were recruited and tested. Results: The overall myelin T1 values are around 80 to 200 ms, and the uT2 fraction is around 10-20%. Impact: This new UTE-based method used simplified model to provide reliable fitting results of uT2 fraction, which was also tested on multiple sclerosis patients, could aid in future multiple sclerosis diagnosis and evaluation of re-myelination during treatment.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 64%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantitative Ultrashort T2 Components Imaging using Variable Flip Angle Balanced Steady State Free Precession Ultrashort Echo Time MRI — Uzay E. Emir, Xin Shen, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS