Adiabatic B1-selective pulses

Motivation: There is a lack of pulse sequences capable of slice selection without B0 gradients that are robust to B0 and B1 inhomogeneity. Goal(s): We aim to create an adiabatic pulse capable of slice selection in a B1 gradient which is robust to B0 and B1 inhomogeneity. Approach: We have applied an amplitude-modulated adiabatic hyperbolic secant (AMHS1) pulse to Hoult's B1-selective rotating frame imaging, which utilizes one B1 field, B1y, as a gradient and another, B1x, for excitation. Results: B1-selective slice inversion is achieved using two AMHS1 pulses with a surface coil at 9.4T on water phantoms. Impact: Slice selection without B0 gradients allows for faster gradient switching, silent scans, and no eddy currents. Low cost, portable MRI systems with no B0 gradients can build off this pulse to recreate more mainstay sequences of clinical MRI.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4418
Primary Topic
Laser-Matter Interactions and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adiabatic B1-selective pulses

Djaudat Idiyatullin, Michael Garwood, Efraín Torres, Saurin Kantesaria
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Laser-Matter Interactions and Applications
article

Adiabatic B1-selective pulses

Djaudat Idiyatullin, Michael Garwood, Efraín Torres, Saurin Kantesaria
article en

Abstract

Motivation: There is a lack of pulse sequences capable of slice selection without B0 gradients that are robust to B0 and B1 inhomogeneity. Goal(s): We aim to create an adiabatic pulse capable of slice selection in a B1 gradient which is robust to B0 and B1 inhomogeneity. Approach: We have applied an amplitude-modulated adiabatic hyperbolic secant (AMHS1) pulse to Hoult's B1-selective rotating frame imaging, which utilizes one B1 field, B1y, as a gradient and another, B1x, for excitation. Results: B1-selective slice inversion is achieved using two AMHS1 pulses with a surface coil at 9.4T on water phantoms. Impact: Slice selection without B0 gradients allows for faster gradient switching, silent scans, and no eddy currents. Low cost, portable MRI systems with no B0 gradients can build off this pulse to recreate more mainstay sequences of clinical MRI.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Laser-Matter Interactions and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Adiabatic B1-selective pulses — Djaudat Idiyatullin, Michael Garwood, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS