Accuracy and precision of R2* and fat-specific R1 from multiparametric relaxation mapping in fat-water mixtures

Motivation: Grouping water- and fat-specific (R2*w and R2*f) into a single parameter (R2*observed) is a common assumption in MRI. However, the current literature does not address how this assumption affects the joint mapping of R1f and R2*. Goal(s): To evaluate the precision and accuracy of R1f and R2*, under the assumptions of single- or dual-R2*. Approach: Accuracy and precision of R2*observed, R2*w, R2*f, and R1f estimates from Fat DESPOT were studied under both assumptions in simulations and phantom experiments. Results: R2*observed was equivalent to R2*w and R2*f for high and low PDFF, respectively; and R1f was not affected by R2*-based assumptions. Impact: We determined that the single-R2* assumption has negligible effects on R1f precision and accuracy while enabling robust and precise estimation of R2*observed. Thus, the single-R2* assumption is a preferable alternative to the dual-R2* assumption.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1666
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy and precision of R2* and fat-specific R1 from multiparametric relaxation mapping in fat-water mixtures

Véronique Fortier, Ives R. Levesque, Jorge Campos Pazmino, Renée-Claude Bider et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Spectroscopy and Chemometric Analyses
article

Accuracy and precision of R2* and fat-specific R1 from multiparametric relaxation mapping in fat-water mixtures

Véronique Fortier, Ives R. Levesque, Jorge Campos Pazmino, Renée-Claude Bider, Nathalie Panov
article en

Abstract

Motivation: Grouping water- and fat-specific (R2*w and R2*f) into a single parameter (R2*observed) is a common assumption in MRI. However, the current literature does not address how this assumption affects the joint mapping of R1f and R2*. Goal(s): To evaluate the precision and accuracy of R1f and R2*, under the assumptions of single- or dual-R2*. Approach: Accuracy and precision of R2*observed, R2*w, R2*f, and R1f estimates from Fat DESPOT were studied under both assumptions in simulations and phantom experiments. Results: R2*observed was equivalent to R2*w and R2*f for high and low PDFF, respectively; and R1f was not affected by R2*-based assumptions. Impact: We determined that the single-R2* assumption has negligible effects on R1f precision and accuracy while enabling robust and precise estimation of R2*observed. Thus, the single-R2* assumption is a preferable alternative to the dual-R2* assumption.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 72%
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.