Metabolite T1 and T2 relaxation times in the macaque brain at 11.7T with local B1+ shimming

Motivation: Knowledge of metabolite T1 and T2 relaxation times is needed for optimal pulse sequence parameterization and to account for partial T1 saturation and T2 decay during metabolite quantification. Goal(s): To measure metabolite relaxation times in the macaque brain at 11.7T with a 6Tx/6Rx surface coil. Approach: Multi-echo and inversion-recovery acquisitions with STEAM combined with a B1+-shimming configuration optimized for the MRS voxel. Results: Performing voxel-specific B1+-shimming reduced the required RF power by 40% (±11%) . Measured T1 values were in agreement with the literature while T2 values were lower than those measured with LASER in the rat brain at 11.7T. Impact: Increased accuracy for metabolite concentration estimation and optimal acquisition parameters to maximize temporal SNR at 11.7T. Parallel transmission elicited a large reduction in the required RF power for a 2.25 mL cortical voxel using a dedicated 6Tx/6Rx surface coil.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0605
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metabolite T1 and T2 relaxation times in the macaque brain at 11.7T with local B1+ shimming

Franck Mauconduit, Alexis Amadon, Marion Gay, Maxime Roustan et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Metabolite T1 and T2 relaxation times in the macaque brain at 11.7T with local B1+ shimming

Franck Mauconduit, Alexis Amadon, Marion Gay, Maxime Roustan, Alfredo L. Lopez Kolkovsky, Fawzi Boumezbeur, Aurélien Massire, Thomas Lilin Froment
article en

Abstract

Motivation: Knowledge of metabolite T1 and T2 relaxation times is needed for optimal pulse sequence parameterization and to account for partial T1 saturation and T2 decay during metabolite quantification. Goal(s): To measure metabolite relaxation times in the macaque brain at 11.7T with a 6Tx/6Rx surface coil. Approach: Multi-echo and inversion-recovery acquisitions with STEAM combined with a B1+-shimming configuration optimized for the MRS voxel. Results: Performing voxel-specific B1+-shimming reduced the required RF power by 40% (±11%) . Measured T1 values were in agreement with the literature while T2 values were lower than those measured with LASER in the rat brain at 11.7T. Impact: Increased accuracy for metabolite concentration estimation and optimal acquisition parameters to maximize temporal SNR at 11.7T. Parallel transmission elicited a large reduction in the required RF power for a 2.25 mL cortical voxel using a dedicated 6Tx/6Rx surface coil.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.