Localization of Non-Isocentric Wrist Anatomy with Few-shot Foundation Models

Motivation: Automatic localization of non-isocentric anatomy such as wrist for autolocalization workflow is challenging due to its flexible scan positions and field of views. In this abstract, we develop and compare capability of few-shot foundation model-based localization of wrist. Goal(s): Develop and compare few-shot foundation models (FM) localization capability for wrist anatomy. Approach: Self-supervised adapter, and convolution neural network (CNN) based inference time few-shot task adaptation models are developed and compared for 3D wrist localization capability. Results: Self-supervised few-shot adapter-based model found to be superior for 3D localization with significantly high localization accuracy and less false positives and false negatives compared to CNN approach. Impact: With as few as 6 labeled images, localization adapter trained with self-supervised visual features performed significantly better than CNN based few-shot model that used as many as 28 image-mask pairs. Demonstrated 3D localization capability from models trained on 2D images.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4003
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Localization of Non-Isocentric Wrist Anatomy with Few-shot Foundation Models

Gurunath Reddy Madhumani, Dattesh Shanbhag, Deepa Anand
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Orthopedic Surgery and Rehabilitation
article

Localization of Non-Isocentric Wrist Anatomy with Few-shot Foundation Models

Gurunath Reddy Madhumani, Dattesh Shanbhag, Deepa Anand
article en

Abstract

Motivation: Automatic localization of non-isocentric anatomy such as wrist for autolocalization workflow is challenging due to its flexible scan positions and field of views. In this abstract, we develop and compare capability of few-shot foundation model-based localization of wrist. Goal(s): Develop and compare few-shot foundation models (FM) localization capability for wrist anatomy. Approach: Self-supervised adapter, and convolution neural network (CNN) based inference time few-shot task adaptation models are developed and compared for 3D wrist localization capability. Results: Self-supervised few-shot adapter-based model found to be superior for 3D localization with significantly high localization accuracy and less false positives and false negatives compared to CNN approach. Impact: With as few as 6 labeled images, localization adapter trained with self-supervised visual features performed significantly better than CNN based few-shot model that used as many as 28 image-mask pairs. Demonstrated 3D localization capability from models trained on 2D images.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 60%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.