Markerless prospective motion correction assisted functional MRS during motor activation using PRESS sequence at 3T

Motivation: Conducting functional magnetic resonance spectroscopy (fMRS) studies in clinical conditions is challenging due to low SNR and small neurochemical changes. Goal(s): Investigate the feasibility of PRESS fMRS studies at 3T assisted by a prospective motion correction (PMC) system. Approach: A markerless PMC system was applied to an fMRS study during motor activation with a task paradigm consisting of three blocks REST-TASK-REST. The same motor task was repeated twice, once with PMC ON and once with PMC OFF. Results: A statistically significant increase in Glx of 5.75% was observed with PMC ON. No metabolite changes were observed with PMC OFF. Impact: With the assistance of a markerless prospective motion correction system, fMRS at 3T with a clinically feasible protocol is capable of detecting small changes of a few percent in Glx concentrations during functional activation.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/0644
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Markerless prospective motion correction assisted functional MRS during motor activation using PRESS sequence at 3T

Assaf Tal, Yanxing Yang, Jiaqi Zhao, Xinyue Zhang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Markerless prospective motion correction assisted functional MRS during motor activation using PRESS sequence at 3T

Assaf Tal, Yanxing Yang, Jiaqi Zhao, Xinyue Zhang, Hao Chen, Yiling Liu, Zhang Zhi-yong, Philip Lee, Wei Yu
article en

Abstract

Motivation: Conducting functional magnetic resonance spectroscopy (fMRS) studies in clinical conditions is challenging due to low SNR and small neurochemical changes. Goal(s): Investigate the feasibility of PRESS fMRS studies at 3T assisted by a prospective motion correction (PMC) system. Approach: A markerless PMC system was applied to an fMRS study during motor activation with a task paradigm consisting of three blocks REST-TASK-REST. The same motor task was repeated twice, once with PMC ON and once with PMC OFF. Results: A statistically significant increase in Glx of 5.75% was observed with PMC ON. No metabolite changes were observed with PMC OFF. Impact: With the assistance of a markerless prospective motion correction system, fMRS at 3T with a clinically feasible protocol is capable of detecting small changes of a few percent in Glx concentrations during functional activation.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.