Phase unwrapping 4D flow MRI by iterative graph cuts

Motivation: Phase unwrapping 4D flow MRI may alleviate time consuming manual identification of velocity aliasing and the need for re-acquisitions. Goal(s): To apply iterative graph cuts (IGC) to 4D flow MRI. Approach: A performance comparison between 3D and 4D unwrapping was conducted using retrospectively wrapped 4D flow MRI datasets. The performance of the proposed IGC method was also compared to ROMEO and a Laplacian-based algorithm. Results: IGC performance improved with unwrapping of 4D flow compared to 3D flow. IGC performed better than, or comparable to, the reference methods in 3D and 4D unwrapping. Impact: The proposed method shows promise for phase unwrapping 4D flow MRI, extending the dynamic range of 4D flow MRI and reduces the need for multi-VENC acquisitions in clinical cardiac MRI.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1824
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase unwrapping 4D flow MRI by iterative graph cuts

Petter Dyverfeldt, Johan Berglund, Tamara Bianchessi, Mio Liljeblad et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Image Segmentation Techniques
article

Phase unwrapping 4D flow MRI by iterative graph cuts

Petter Dyverfeldt, Johan Berglund, Tamara Bianchessi, Mio Liljeblad, Sohaib A. Qazi
article en

Abstract

Motivation: Phase unwrapping 4D flow MRI may alleviate time consuming manual identification of velocity aliasing and the need for re-acquisitions. Goal(s): To apply iterative graph cuts (IGC) to 4D flow MRI. Approach: A performance comparison between 3D and 4D unwrapping was conducted using retrospectively wrapped 4D flow MRI datasets. The performance of the proposed IGC method was also compared to ROMEO and a Laplacian-based algorithm. Results: IGC performance improved with unwrapping of 4D flow compared to 3D flow. IGC performed better than, or comparable to, the reference methods in 3D and 4D unwrapping. Impact: The proposed method shows promise for phase unwrapping 4D flow MRI, extending the dynamic range of 4D flow MRI and reduces the need for multi-VENC acquisitions in clinical cardiac MRI.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.