Impact of Implant Manufacturing Variability & Number of Measurements on Assessing RF-Induced Lead Heating & Injection Voltage

Motivation: Establishing a validated predictive ISO/TS 10974:2018 Tier 3 model for RF-induced lead heating and injection voltage of an implantable medical device can be extensive and time-consuming. Goal(s): Investigate the impact of lead manufacturing variability and number of in-vitro measurements on the resulting model's Transfer Function scalar, A. Approach: Lead heating or injection voltage was assessed for SCS and DBS systems for a varying number of samples and measurements and the resulting A values were compared. Results: The impact on A was minimal and as few as six measurements of one lead sample can develop a reliable model. Impact: Optimization of the needed number of in-vitro radiated measurements and active implantable medical device (AIMD) lead samples for ISO/TS 10974:2018 Tier 3 based Clause 8 (RF-induced lead heating) and Clause 15 (RF-induced injection voltage) MR Conditional safety assessments.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1312
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Implant Manufacturing Variability & Number of Measurements on Assessing RF-Induced Lead Heating & Injection Voltage

Nowrin H. Chamok, Klaus Bond, L. Al-Dayeh, C.Y. Kwok et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Dental Implant Techniques and Outcomes
article

Impact of Implant Manufacturing Variability & Number of Measurements on Assessing RF-Induced Lead Heating & Injection Voltage

Nowrin H. Chamok, Klaus Bond, L. Al-Dayeh, C.Y. Kwok, Arash Dabir, Anasheh Avakians
article en

Abstract

Motivation: Establishing a validated predictive ISO/TS 10974:2018 Tier 3 model for RF-induced lead heating and injection voltage of an implantable medical device can be extensive and time-consuming. Goal(s): Investigate the impact of lead manufacturing variability and number of in-vitro measurements on the resulting model's Transfer Function scalar, A. Approach: Lead heating or injection voltage was assessed for SCS and DBS systems for a varying number of samples and measurements and the resulting A values were compared. Results: The impact on A was minimal and as few as six measurements of one lead sample can develop a reliable model. Impact: Optimization of the needed number of in-vitro radiated measurements and active implantable medical device (AIMD) lead samples for ISO/TS 10974:2018 Tier 3 based Clause 8 (RF-induced lead heating) and Clause 15 (RF-induced injection voltage) MR Conditional safety assessments.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.