Rapid Monitoring of Glycogen Dynamics: MRS-based T1 and T2 Water Relaxation Times as potential surrogates for 13C-MRS

Motivation: The limited temporal resolution and accessibility of 13C-MRS restrict studying rapid glycogen changes. Since glycogen influences water relaxation times by binding water, water relaxation measurements by 1H-MRS may offer a faster alternative to monitor glycogen content dynamically. Goal(s): This study assesses water relaxation time measurements using 1H-MRS as a surrogate for glycogen. Approach: Water T1 and T2 relaxation times were measured with 1H-MRS in phantoms and in vivo. Glycogen was quantified using 13C-MRS. Measurements were performed before and after ingestion of 75g of glucose. Results: Water T1 correlated better with glycogen levels and detected post-glucose dynamic changes in liver and muscle tissue. Impact: We demonstrate that water T1 relaxation time measured by 1H-MRS could provide a faster, accessible alternative to 13C-MRS for glycogen detection, enabling real-time, simultaneous measurement of glycogen dynamics across multiple organs.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1731
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Monitoring of Glycogen Dynamics: MRS-based T1 and T2 Water Relaxation Times as potential surrogates for 13C-MRS

Kim Brouwers, Julian Mevenkamp, Mijke Buitinga, Vera B. Schrauwen‐Hinderling et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Rapid Monitoring of Glycogen Dynamics: MRS-based T1 and T2 Water Relaxation Times as potential surrogates for 13C-MRS

Kim Brouwers, Julian Mevenkamp, Mijke Buitinga, Vera B. Schrauwen‐Hinderling, Florian Haans
article en

Abstract

Motivation: The limited temporal resolution and accessibility of 13C-MRS restrict studying rapid glycogen changes. Since glycogen influences water relaxation times by binding water, water relaxation measurements by 1H-MRS may offer a faster alternative to monitor glycogen content dynamically. Goal(s): This study assesses water relaxation time measurements using 1H-MRS as a surrogate for glycogen. Approach: Water T1 and T2 relaxation times were measured with 1H-MRS in phantoms and in vivo. Glycogen was quantified using 13C-MRS. Measurements were performed before and after ingestion of 75g of glucose. Results: Water T1 correlated better with glycogen levels and detected post-glucose dynamic changes in liver and muscle tissue. Impact: We demonstrate that water T1 relaxation time measured by 1H-MRS could provide a faster, accessible alternative to 13C-MRS for glycogen detection, enabling real-time, simultaneous measurement of glycogen dynamics across multiple organs.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.