Cryogenic RF coil versus higher magnetic field strength for 1H fast FID-MRSI in the rat brain

Motivation: MRSI in small rodents is challenging due to inherent low sensitivity. This could be alleviated by higher magnetic field strengths or cryogenic RF coils. Goal(s): Compare 1H FID-MRSI in the rat brain between 9.4T with a cryogenic coil and 14.1T with a room-temperature coil. Approach: The quality of metabolic maps obtained from both setups was compared Results: Overall, both setups achieve metabolic quantification and mapping of similar qualities. The 9.4T setup provides better spatial coverage, higher SNR and more homogeneous B0, while the 14.1T benefits from better spectral resolution. Impact: High quality metabolite quantification and mapping with fast 1H FID-MRSI is achieved in the rat brain benefiting from either the unmatched sensitivity of cryogenic coils at 9.4T, or enhanced spectral resolution at 14.1T.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/5240
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cryogenic RF coil versus higher magnetic field strength for 1H fast FID-MRSI in the rat brain

Bernard Lanz, Thanh Phong Lê, Jessie Mosso, Cristina Cudalbu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Cryogenic RF coil versus higher magnetic field strength for 1H fast FID-MRSI in the rat brain

Bernard Lanz, Thanh Phong Lê, Jessie Mosso, Cristina Cudalbu, Brayan Alves
article en

Abstract

Motivation: MRSI in small rodents is challenging due to inherent low sensitivity. This could be alleviated by higher magnetic field strengths or cryogenic RF coils. Goal(s): Compare 1H FID-MRSI in the rat brain between 9.4T with a cryogenic coil and 14.1T with a room-temperature coil. Approach: The quality of metabolic maps obtained from both setups was compared Results: Overall, both setups achieve metabolic quantification and mapping of similar qualities. The 9.4T setup provides better spatial coverage, higher SNR and more homogeneous B0, while the 14.1T benefits from better spectral resolution. Impact: High quality metabolite quantification and mapping with fast 1H FID-MRSI is achieved in the rat brain benefiting from either the unmatched sensitivity of cryogenic coils at 9.4T, or enhanced spectral resolution at 14.1T.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cryogenic RF coil versus higher magnetic field strength for 1H fast FID-MRSI in the rat brain — Bernard Lanz, Thanh Phong Lê, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS