A Mixed Precision Conjugate Gradient Method for Efficient Iterative MRI reconstruction
Motivation: Iterative MRI reconstruction algorithms are computational expensive requiring expensive compute to implement. Goal(s): Investigate the feasibility of mixed-precision arithmetic for an iterative MRI reconstruction algorithm. Approach: Different mixed precision versions of conjugate gradient method were implemented with 32-bit floating point, 16-bit floating point, and 8-bit floating point representations and the quality of the reconstructed image was assessed. Results: The mixed-precision floating point 8-bit algorithm shows numerical instability but decent performance with an increased in regularization compared to 32-bit and 16-bit floating point versions. Impact: Iterative reconstruction algorithms could possibly be implemented on low performance and cheaper compute hardware with further algorithmic stability enhancements.
Authors
- Nikhil Deveshwar (ORCID: https://orcid.org/0000-0002-5516-3769)
- Peder E. Z. Larson (ORCID: https://orcid.org/0000-0003-4183-3634)
Publication Details
- Journal
- Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
- Published
- 2025-09-16
- DOI
- https://doi.org/10.58530/2025/5228
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00