dB/dt Camera for Gradient Eddy Current Mapping Outside the Magnet

Motivation: Commercial dynamic field camera measures gradient eddy current fields in the magnet, where magnet eddy current can confound gradient coil's internal eddy current fields. Goal(s): To develop a field monitoring device, called dB/dt camera, to map short-time-constant eddy current fields on a standalone gradient coil. Approach: A circular array of 22 untuned pickup coils was placed inside two different gradient coils outside the magnet and the step response functions were measured and compared. Results: Eddy current fields with time constant ~100 μs were measured consistent with prior imaging results. The amplitudes correlated with the thickness of the conductors of the gradient coils. Impact: The proposed method enables time-resolved gradient eddy current field mapping without the magnet or power electronics. The method can help isolate eddy current sources in the gradient coil or RF subsystem.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1338
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

dB/dt Camera for Gradient Eddy Current Mapping Outside the Magnet

Seung‐Kyun Lee, Richard S Hinks
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Non-Destructive Testing Techniques
article

dB/dt Camera for Gradient Eddy Current Mapping Outside the Magnet

Seung‐Kyun Lee, Richard S Hinks
article en

Abstract

Motivation: Commercial dynamic field camera measures gradient eddy current fields in the magnet, where magnet eddy current can confound gradient coil's internal eddy current fields. Goal(s): To develop a field monitoring device, called dB/dt camera, to map short-time-constant eddy current fields on a standalone gradient coil. Approach: A circular array of 22 untuned pickup coils was placed inside two different gradient coils outside the magnet and the step response functions were measured and compared. Results: Eddy current fields with time constant ~100 μs were measured consistent with prior imaging results. The amplitudes correlated with the thickness of the conductors of the gradient coils. Impact: The proposed method enables time-resolved gradient eddy current field mapping without the magnet or power electronics. The method can help isolate eddy current sources in the gradient coil or RF subsystem.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 75%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.