Optimal scan parameters for DWI with reverse encoding distortion correction: a phantom study and clinical feasibility study in the pancreas.

Motivation: Challenges in pancreatic DWI include image distortion due to air in the gastrointestinal tract. Goal(s): Our goal was to find optimal imaging parameters for the application of reverse encoding distortion correction (RDC) and to evaluate its value in pancreatic DWI. Approach: Phantom and clinical studies were conducted using a 3.0T MRI scanner. Results: In the phantom study, RDC effectively reduced DWI distortion independent of parallel imaging factor and bandwidth. In the clinical study, RDC with a lower parallel imaging factor and bandwidth enabled the acquisition of high-SNR, high-resolution pancreatic DWI while minimizing image distortion. Impact: To maximize the value of the RDC technique in DWI, the parallel imaging factor and bandwidth should be reduced because RDC efficiently reduces image distortion and the lower parallel imaging factor and bandwidth increase SNR and enable high-resolution DWI.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2164
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal scan parameters for DWI with reverse encoding distortion correction: a phantom study and clinical feasibility study in the pancreas.

Ryuji Shimada, Yuichiro Somiya, Takahiro Tsuboyama, A. Kusaka et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Ultrasound Imaging and Elastography
article

Optimal scan parameters for DWI with reverse encoding distortion correction: a phantom study and clinical feasibility study in the pancreas.

Ryuji Shimada, Yuichiro Somiya, Takahiro Tsuboyama, A. Kusaka, Keitaro Sofue, Shintaro Horii, Naoki Yoshida, Tomohiro Noda, Kazuyoshi Tsukamoto, Takamichi Murakami
article en

Abstract

Motivation: Challenges in pancreatic DWI include image distortion due to air in the gastrointestinal tract. Goal(s): Our goal was to find optimal imaging parameters for the application of reverse encoding distortion correction (RDC) and to evaluate its value in pancreatic DWI. Approach: Phantom and clinical studies were conducted using a 3.0T MRI scanner. Results: In the phantom study, RDC effectively reduced DWI distortion independent of parallel imaging factor and bandwidth. In the clinical study, RDC with a lower parallel imaging factor and bandwidth enabled the acquisition of high-SNR, high-resolution pancreatic DWI while minimizing image distortion. Impact: To maximize the value of the RDC technique in DWI, the parallel imaging factor and bandwidth should be reduced because RDC efficiently reduces image distortion and the lower parallel imaging factor and bandwidth increase SNR and enable high-resolution DWI.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.