The variability of mean ADC measurements with simultaneous multi-slice imaging in a NIST/QIBA diffusion phantom.

Motivation: Long MRI scan times limit patient throughput, degrades patient experience and can lead to motion that can have adverse effects on quantitative MRI measurements. Goal(s): Assess the impact of using simultaneous multi-slice (SMS) imaging on the accuracy and reproducibility of ADC measurements. Approach: The CaliberMRI diffusion phantom with full traceability through the National Institute of Standards and Technology (NIST) was imaged using a DWI sequence. Different SMS factors were applied in this multi-vendor study. Results: Mean ADC becomes less accurate and less reproducible as SMS factor increases. The highest errors were seen in solutions with the highest ADC values. Impact: Using SMS factors of 2 has the potential to speed up MRI DWI acquisitions without biasing ADC, improving patient experience and throughput while reducing motion artefacts. However, higher SMS factors may be unreliable, particularly at higher ADC values.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1673
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The variability of mean ADC measurements with simultaneous multi-slice imaging in a NIST/QIBA diffusion phantom.

Todor Karaulanov, Matthew Marzetti, Stewart Boyd, Gráinne Bourke et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

The variability of mean ADC measurements with simultaneous multi-slice imaging in a NIST/QIBA diffusion phantom.

Todor Karaulanov, Matthew Marzetti, Stewart Boyd, Gráinne Bourke, Ryckie G. Wade, Y.F. Wang, Irvin Teh, Peter Duce
article en

Abstract

Motivation: Long MRI scan times limit patient throughput, degrades patient experience and can lead to motion that can have adverse effects on quantitative MRI measurements. Goal(s): Assess the impact of using simultaneous multi-slice (SMS) imaging on the accuracy and reproducibility of ADC measurements. Approach: The CaliberMRI diffusion phantom with full traceability through the National Institute of Standards and Technology (NIST) was imaged using a DWI sequence. Different SMS factors were applied in this multi-vendor study. Results: Mean ADC becomes less accurate and less reproducible as SMS factor increases. The highest errors were seen in solutions with the highest ADC values. Impact: Using SMS factors of 2 has the potential to speed up MRI DWI acquisitions without biasing ADC, improving patient experience and throughput while reducing motion artefacts. However, higher SMS factors may be unreliable, particularly at higher ADC values.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The variability of mean ADC measurements with simultaneous multi-slice imaging in a NIST/QIBA diffusion phantom. — Todor Karaulanov, Matthew Marzetti, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS