Correction of Resting-State fMRI Data Contaminated by B0 Inhomogeneity Artifacts Using a Single-Subject Fitting Neural Network

Motivation: A primary limitation of Gradient Echo-EPI(GRE-EPI) is its sensitivity to B0 inhomogeneity, resulting in signal dropout at air/tissue interfaces. Current artifact correction methods, however, continue to face substantial limitation. Goal(s): We aim to develop a frequency domain based single subject fitting neural network to effectively reduce B0 field inhomogeneity artifacts. Approach: Spin Echo EPI is resilient to B0 inhomogeneity but less T2*-sensitive. GRE EPI is T2*-sensitive but prone to B0 inhomogeneity. Leveraging these properties, we proposed a single-subject fitting neural network. Results: The proposed method mitigated the B0 filed inhomogeneity artifacts and restored brain signals. Impact: B0 field inhomogeneity induced artifacts were mitigated by proposed frequency-domain deconvolutional neural network. The proposed method is expected to broaden the detectable range of brain regions, particularly in areas heavily affected by B0 inhomogeneity, enabling more comprehensive whole-brain fMRI research.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1580
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correction of Resting-State fMRI Data Contaminated by B0 Inhomogeneity Artifacts Using a Single-Subject Fitting Neural Network

SooHyoung Lee, Kyung Uk Jung, Dong Wook Kim, Donghyun Kim et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Correction of Resting-State fMRI Data Contaminated by B0 Inhomogeneity Artifacts Using a Single-Subject Fitting Neural Network

SooHyoung Lee, Kyung Uk Jung, Dong Wook Kim, Donghyun Kim, Hyunjoo Song, S.M. Seo
article en

Abstract

Motivation: A primary limitation of Gradient Echo-EPI(GRE-EPI) is its sensitivity to B0 inhomogeneity, resulting in signal dropout at air/tissue interfaces. Current artifact correction methods, however, continue to face substantial limitation. Goal(s): We aim to develop a frequency domain based single subject fitting neural network to effectively reduce B0 field inhomogeneity artifacts. Approach: Spin Echo EPI is resilient to B0 inhomogeneity but less T2*-sensitive. GRE EPI is T2*-sensitive but prone to B0 inhomogeneity. Leveraging these properties, we proposed a single-subject fitting neural network. Results: The proposed method mitigated the B0 filed inhomogeneity artifacts and restored brain signals. Impact: B0 field inhomogeneity induced artifacts were mitigated by proposed frequency-domain deconvolutional neural network. The proposed method is expected to broaden the detectable range of brain regions, particularly in areas heavily affected by B0 inhomogeneity, enabling more comprehensive whole-brain fMRI research.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Correction of Resting-State fMRI Data Contaminated by B0 Inhomogeneity Artifacts Using a Single-Subject Fitting Neural Network — SooHyoung Lee, Kyung Uk Jung, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS