Comparing BOLD contamination in CBV-based fMRI with conventional EPI and echo-planar time-resolved imaging (EPTI) at 7 T

Motivation: Non-BOLD functional imaging contrasts like CBV-weighted VASO-fMRI often use EPI-based readouts, which are prone to BOLD contamination from non-zero echo times and non-zero echo-train lengths. Goal(s): Echo-planar time-resolved Imaging (EPTI) is a new readout strategy that allows dense reconstruction of multiple echoes with minimal echo train length. Approach: This study evaluates residual BOLD effects in BOLD-corrected VASO using EPI and compares these to EPTI extrapolated to zero echo time. Results: Findings show that BOLD correction alone does not fully eliminate residual contamination in VASO, and that EPTI exhibits unexpected signal changes that may reflect residual BOLD or non-BOLD components. Impact: This work underscores the limitations of conventional BOLD correction techniques for VASO fMRI and evaluates EPTI for removing unwanted BOLD contamination. Both approaches appear unable to isolate pure CBV weighting in VASO data.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2500
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing BOLD contamination in CBV-based fMRI with conventional EPI and echo-planar time-resolved imaging (EPTI) at 7 T

Fuyixue Wang, Daniel Haenelt, Jon̈athan R. Polimeni, Zijing Dong et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Comparing BOLD contamination in CBV-based fMRI with conventional EPI and echo-planar time-resolved imaging (EPTI) at 7 T

Fuyixue Wang, Daniel Haenelt, Jon̈athan R. Polimeni, Zijing Dong, Zhangxuan Hu, Kawin Setsompop
article en

Abstract

Motivation: Non-BOLD functional imaging contrasts like CBV-weighted VASO-fMRI often use EPI-based readouts, which are prone to BOLD contamination from non-zero echo times and non-zero echo-train lengths. Goal(s): Echo-planar time-resolved Imaging (EPTI) is a new readout strategy that allows dense reconstruction of multiple echoes with minimal echo train length. Approach: This study evaluates residual BOLD effects in BOLD-corrected VASO using EPI and compares these to EPTI extrapolated to zero echo time. Results: Findings show that BOLD correction alone does not fully eliminate residual contamination in VASO, and that EPTI exhibits unexpected signal changes that may reflect residual BOLD or non-BOLD components. Impact: This work underscores the limitations of conventional BOLD correction techniques for VASO fMRI and evaluates EPTI for removing unwanted BOLD contamination. Both approaches appear unable to isolate pure CBV weighting in VASO data.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparing BOLD contamination in CBV-based fMRI with conventional EPI and echo-planar time-resolved imaging (EPTI) at 7 T — Fuyixue Wang, Daniel Haenelt, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS