High-Resolution Free Breathing LGE With Cascaded Compressed Sensing, Automatic Frame Selection and Integrated Motion Correction

Motivation: We noticed that free breathing motion corrected averaged single shot (FB MOCO AVG 1S) SSFP LGE is not as T1-sensitive as segmented breath held (BH) GRE. Goal(s): Therefore, we aimed to create a GRE version of FB MOCO AVG 1S combining the T1-sensitivity of segmented BH GRE with the versatility of FB MOCO AVG 1S. Approach: Compressed sensing (CS) enabled a T1-sensitive GRE readout with high SNR, spatial and temporal resolution traditionally only achievable by SSFP. Results: We created a CS GRE FB MOCO AVG 1S technique with improved sharpness, SNR, and T1-sensitivity compared to existing FB SSFP and equal to BH GRE. Impact: The proposed free breathing compressed sensing GRE LGE technique could enable studying subtle hyperenhancement concurrent with non-ischemic disease, sometimes not picked up by SSFP. Patients unable to breath hold can be included in studies traditionally only feasible with breath holds.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/4599
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Resolution Free Breathing LGE With Cascaded Compressed Sensing, Automatic Frame Selection and Integrated Motion Correction

Wolfgang Rehwald, Céleste Chevalier, Jennifer R. Shelton, K. Han Kim et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Fiber Optic Sensors
article

High-Resolution Free Breathing LGE With Cascaded Compressed Sensing, Automatic Frame Selection and Integrated Motion Correction

Wolfgang Rehwald, Céleste Chevalier, Jennifer R. Shelton, K. Han Kim, George Gamoneda, David C. Wendell, Nestor Mena, Raymond Kim, Stephen Darty, Susan Bender, Sherilyn Pirela, Tulio Bonesi Alvarenga, Kayla Morabito
article en

Abstract

Motivation: We noticed that free breathing motion corrected averaged single shot (FB MOCO AVG 1S) SSFP LGE is not as T1-sensitive as segmented breath held (BH) GRE. Goal(s): Therefore, we aimed to create a GRE version of FB MOCO AVG 1S combining the T1-sensitivity of segmented BH GRE with the versatility of FB MOCO AVG 1S. Approach: Compressed sensing (CS) enabled a T1-sensitive GRE readout with high SNR, spatial and temporal resolution traditionally only achievable by SSFP. Results: We created a CS GRE FB MOCO AVG 1S technique with improved sharpness, SNR, and T1-sensitivity compared to existing FB SSFP and equal to BH GRE. Impact: The proposed free breathing compressed sensing GRE LGE technique could enable studying subtle hyperenhancement concurrent with non-ischemic disease, sometimes not picked up by SSFP. Patients unable to breath hold can be included in studies traditionally only feasible with breath holds.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-Resolution Free Breathing LGE With Cascaded Compressed Sensing, Automatic Frame Selection and Integrated Motion Correction — Wolfgang Rehwald, Céleste Chevalier, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS