Quantitative Macromolecular Proton Fraction Imaging using Pulsed Spin-Lock

Motivation: MPF-SL is a promising technique for MPF mapping in vivo. But its SNR can be limited by the RF hardware constraints in certain applications. Goal(s): We propose a pulsed spin-lock technique to address the hardware constrain from the RF amplifier in MPF mapping using spin-lock. Approach: The proposed method is validated using Bloch-McConnell simulation, phantom and in vivo experiments. Results: The proposed method significantly enhances the total spin-lock duration using standard hardware in a clinical MRI system, and the results demonstrate its insensitivity to the parameters of water pool. Furthermore, it achieves a higher SNR compared to conventional MPF-SL method. Impact: The technical can improve SNR of MPF-SL under typical RF hardware constrain and provide more reliable and robust MPF mapping in vivo.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2010
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Macromolecular Proton Fraction Imaging using Pulsed Spin-Lock

Weitian Chen, Z. Yu, Vincent Wong, Baiyan Jiang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Electron Microscopy Techniques and Applications
article

Quantitative Macromolecular Proton Fraction Imaging using Pulsed Spin-Lock

Weitian Chen, Z. Yu, Vincent Wong, Baiyan Jiang, Queenie Chan, Qianxue Shan, Chiu‐Wing Winnie Chu, Jian Hou, Qiuyi Shen
article en

Abstract

Motivation: MPF-SL is a promising technique for MPF mapping in vivo. But its SNR can be limited by the RF hardware constraints in certain applications. Goal(s): We propose a pulsed spin-lock technique to address the hardware constrain from the RF amplifier in MPF mapping using spin-lock. Approach: The proposed method is validated using Bloch-McConnell simulation, phantom and in vivo experiments. Results: The proposed method significantly enhances the total spin-lock duration using standard hardware in a clinical MRI system, and the results demonstrate its insensitivity to the parameters of water pool. Furthermore, it achieves a higher SNR compared to conventional MPF-SL method. Impact: The technical can improve SNR of MPF-SL under typical RF hardware constrain and provide more reliable and robust MPF mapping in vivo.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 89%
Advanced Electron Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.