3D EPI Performance in Detecting Microhemorrhage, Compared to 2D GRE

Motivation: Improve detection sensitivity while maintaining reasonable scan times. Goal(s): Assess how the newly available, 3D Echo Planar Imaging (EPI), performs when compared to 2D GRE in detection of cerebral microhemorrhages (mH). Approach: Conducted on 15 patients with confirmed mHs, and independently reviewed the 2D GRE and 3D EPI images to assess the number and distribution of definite mH and possible mH. Results: 3D EPI sequence allowed the detection of 26 definite and 3 possible mHs, compared to 17 definite and 8 possible mHs identified by the 2D GRE sequence. 3D EPI was comparable to 2D GRE at approximately 1 minute of scan time. Impact: The introduction of 3D EPI as a fast, highly sensitive pulse sequence for detecting microhemorrhages could aid in MRI-based diagnosis in neurodegenerative diseases.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1798
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D EPI Performance in Detecting Microhemorrhage, Compared to 2D GRE

Suchandrima Banerjee, Dan Rettmann, Petrice Cogswell, Tim Sprenger et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
ECG Monitoring and Analysis
article

3D EPI Performance in Detecting Microhemorrhage, Compared to 2D GRE

Suchandrima Banerjee, Dan Rettmann, Petrice Cogswell, Tim Sprenger, Brice Fernandez, Steven Anthony Messina, Ian Langenfeld
article en

Abstract

Motivation: Improve detection sensitivity while maintaining reasonable scan times. Goal(s): Assess how the newly available, 3D Echo Planar Imaging (EPI), performs when compared to 2D GRE in detection of cerebral microhemorrhages (mH). Approach: Conducted on 15 patients with confirmed mHs, and independently reviewed the 2D GRE and 3D EPI images to assess the number and distribution of definite mH and possible mH. Results: 3D EPI sequence allowed the detection of 26 definite and 3 possible mHs, compared to 17 definite and 8 possible mHs identified by the 2D GRE sequence. 3D EPI was comparable to 2D GRE at approximately 1 minute of scan time. Impact: The introduction of 3D EPI as a fast, highly sensitive pulse sequence for detecting microhemorrhages could aid in MRI-based diagnosis in neurodegenerative diseases.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.